<?xml version="1.0"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/"><rdf:Description rdf:about="https://dk.um.si/IzpisGradiva.php?id=25913"><dc:title>Non-destructive method for inward leakage detection of a plate evaporator</dc:title><dc:creator>Hribernik,	Aleš	(Avtor)
	</dc:creator><dc:subject>refrigeration</dc:subject><dc:subject>refrigerant leakage</dc:subject><dc:subject>plate evaporator</dc:subject><dc:subject>measurements</dc:subject><dc:subject>non-destructive method</dc:subject><dc:description>A new non-destructive method was developed for the detection of refrigerant leakage at an evaporator`s inflow. Nitrogen and oxygen gas were successively blown through the evaporator. A gas analyser was applied at the outflow of the evaporator and the oxygen concentration measured. It was possible to detect any leakage by investigating the oxygen concentration-time history diagram.</dc:description><dc:date>2007</dc:date><dc:date>2012-05-31 11:26:56</dc:date><dc:type>Neznano</dc:type><dc:identifier>25913</dc:identifier><dc:language>sl</dc:language></rdf:Description></rdf:RDF>