| Naslov: | Influence of water scale on thermal flow losses of domestic appliances |
|---|
| Avtorji: | ID Urbancl, Danijela (Avtor) ID Goričanec, Darko (Avtor) |
| Datoteke: | http://www.naun.org/journals/m3as/mmmas-8.pdf
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Neznano |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FKKT - Fakulteta za kemijo in kemijsko tehnologijo
|
|---|
| Opis: | Research results of how the precipitated water scale on heaters of small domestic appliances influences the consumption of electricity are presented. It shows that the majority of water scale samples are composed of aragonite, calcite and dolomite and that those components have an extraordinary low thermal conductivity. Also, the results show that at 2 mm thick deposit, depending on the chemical composition of water scale, the thermal flow is reduced for 10% to 40%; consequently, the consumption of electricity significantly increases. |
|---|
| Ključne besede: | electricity, heat transfer, heat flow, heat exchanger, water scale |
|---|
| Leto izida: | 2007 |
|---|
| PID: | 20.500.12556/DKUM-26068  |
|---|
| UDK: | 628.162:537.84 |
|---|
| COBISS.SI-ID: | 12315670  |
|---|
| ISSN pri članku: | Y506-2152 |
|---|
| NUK URN: | URN:SI:UM:DK:P89SJ78E |
|---|
| Datum objave v DKUM: | 31.05.2012 |
|---|
| Število ogledov: | 2536 |
|---|
| Število prenosov: | 73 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |