| Naslov: | Comparison of methods for detection of four common nosocomial pathogens on hospital textiles |
|---|
| Avtorji: | ID Fijan, Sabina (Avtor) ID Šostar-Turk, Sonja (Avtor) ID Rozman, Urška (Avtor) |
| Datoteke: | Zdravstveno_varstvo_2014_Fijan,_Turk,_Rozman_Comparison_of_methods_for_detection_of_four_common_nosocomial_pathogens_on_hospital_textile.pdf (811,70 KB) MD5: C7CAD244DB60A3EACEE0E2890F195E17
http://www.degruyter.com/view/j/sjph.2014.53.issue-1/sjph-2014-0003/sjph-2014-0003.xml
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Znanstveno delo |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FZV - Fakulteta za zdravstvene vede
|
|---|
| Opis: | Introduction: Although the most common vehicle for transmission of health-care acquired infections is the personto- person transmission route, the role of environment should not be ignored and hospital linen may contribute to the spreading of nosocomial infections. The contact plate method and swabbing are common methods for sampling microorganisms on textiles; however, results are available after two days as they are based on incubation followed by phenotypeidentification. An important alternative is using quick wash-off methods followed by PCR detection, which shortens the identification process from two days to a few hours.
Methods: The following test microorganisms at different concentrations were inoculated onto textile swatches and dried overnight: Staphylococcus aureus, Klebsiella pneumoniae, Pseudomonas aeruginosa and Clostridium difficile. RODAC plate sampling as well as a non-destructive wash-off method for capturing microorganisms from the textilesusing a Morapex device were used. The elution suspension from the Morapex device was used for two methods. In the first method, classical incubation on selective media followed by phenotypic identification was used and in the second method DNA was extracted from the elution suspension followed by amplification and agarose gel electrophoresis to visualize amplified products.
Conclusions: All chosen bacteria were found using all methods. However, the most sensitive proved to be detection using PCR amplification as we detected the sample with initial concentration of 102 cfu/mL inoculated onto the textile surface before drying. The final detectablerecovered bacterial concentration on textiles was up to 10 cfu/mL. |
|---|
| Ključne besede: | health care associated infections, hospital textiles, Staphylococcus aureus, Klebsiella pneumoniae, Pseudomonas aeruginosa, Clostridium difficile, Morapex |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Leto izida: | 2014 |
|---|
| Št. strani: | str. 17-25 |
|---|
| Številčenje: | Letn. 53, št. 1 |
|---|
| PID: | 20.500.12556/DKUM-65444  |
|---|
| ISSN: | 0351-0026 |
|---|
| UDK: | 616.9:677.021 |
|---|
| COBISS.SI-ID: | 1966756  |
|---|
| DOI: | 10.2478/sjph-2014-0003  |
|---|
| ISSN pri članku: | 0351-0026 |
|---|
| NUK URN: | URN:SI:UM:DK:ICMI5EU5 |
|---|
| Datum objave v DKUM: | 05.04.2017 |
|---|
| Število ogledov: | 2454 |
|---|
| Število prenosov: | 468 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |