| Naslov: | Combination of lung ultrasound (a comet-tail sign) and N-terminal pro-brain natriuretic peptide in differentiating acute heart failure from chronic obstructive pulmonary disease and asthma as cause of acute dyspnea in prehospital emergency setting |
|---|
| Avtorji: | ID Prosen, Gregor (Avtor) ID Klemen, Petra (Avtor) ID Strnad, Matej (Avtor) ID Grmec, Štefek (Avtor) |
| Datoteke: | Critical_Care_2011_Prosen_et_al._Combination_of_lung_ultrasound_(a_comet-tail_sign)_and_N-terminal_pro-brain_natriuretic_peptide_in_diff.pdf (420,76 KB) MD5: A9152657A06A7BF9CB630E7278001024
http://ccforum.biomedcentral.com/articles/10.1186/cc10140
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Znanstveno delo |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | MF - Medicinska fakulteta
|
|---|
| Opis: | Introduction: We studied the diagnostic accuracy of bedside lung ultrasound (the presence of a comet tail sign), N-terminal pro-brain natriuretic peptide (NT-proBNP), and clinical assessment (modified Boston criteria) in differentiating heart failure (HF)- related acute dyspnea from pulmonary (COPD/asthma) related acute dyspnea in the prehospital setting.
Methods: Prospective study was performed at the Center for Emergency Medicine Maribor, Slovenia, between July 2007 and April 2010. Two groups of patients were compared: HF-related acute dyspnea group (n = 129) vs pulmonary-related (asthma/COPD) acute dyspnea group (n = 89). All patients underwent lung ultrasound examination, along with basic laboratory, rapid NT-proBNP testing and chest X-ray.
Results: Ultrasound comet tail sign has 100% sensitivity, 95% specificity, 100% negative predictive value (NPV) and 96% positive predictive value (PPV) for the diagnosis of HF. NT-proBNP (cut-off point 1000 pg/ml) has 92% sensitivity, 89% specificity, 86% NPV and 90% PPV. Boston modified criteria have 85% sensitivity, 86% specificity, 80% NPV and 90% PPV. Comparing the three methods, we found significant differences between ultrasound sign vs NT-proBNP (P<0.05) and Boston modified criteria (P<0.05). Combination of ultrasound sign and NT-proBNP has 100% sensitivity, 100% specificity, 100% NPV and 100% PPV. With ultrasound we can exclude HF in patients with pulmonary related dyspnea who have positive NT-proBNP (> 1000 pg/ml) and previous history of HF.
Conclusions: Ultrasound comet tail sign alone or in combination with NT-proBNP has a high diagnostic accuracy in differentiating between acute HF and COPD/asthma causes of acute dyspnea in prehospital emergency setting. |
|---|
| Ključne besede: | lungs, ultrasound, N-terminal pro-brain natriuretic peptide, acute heart failure, chronic obstructive pulmonary disease, asthma, acute dyspnea |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Leto izida: | 2011 |
|---|
| Št. strani: | str. 1-9 |
|---|
| Številčenje: | Letn. 15 |
|---|
| PID: | 20.500.12556/DKUM-66511  |
|---|
| ISSN: | 1466-609X |
|---|
| UDK: | 616.24-008.4-083.98 |
|---|
| COBISS.SI-ID: | 3911231  |
|---|
| DOI: | 10.1186/cc10140  |
|---|
| ISSN pri članku: | 1466-609X |
|---|
| NUK URN: | URN:SI:UM:DK:KXEEWJ6W |
|---|
| Datum objave v DKUM: | 29.06.2017 |
|---|
| Število ogledov: | 2198 |
|---|
| Število prenosov: | 423 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |