| Naslov: | Force measurements on teeth using fixed orthodontic systems |
|---|
| Avtorji: | ID Rudolf, Rebeka (Avtor) ID Ferčec, Janko (Avtor) |
| Datoteke: | Vojnotehnicki_glasnik_2013_Rudolf,_Fercec_Force_measurements_on_teeth_using_fixed_orthodontic_systems.pdf (1,33 MB) MD5: 712E73DE32EA0EB4F832AE6056ACD819 PID: 20.500.12556/dkum/84e35e15-1cc1-4b8c-840a-cba3e96abccb
http://scindeks.ceon.rs/Article.aspx?artid=0042-84691302105R
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Znanstveno delo |
|---|
| Tipologija: | 1.02 - Pregledni znanstveni članek |
|---|
| Organizacija: | FS - Fakulteta za strojništvo
|
|---|
| Opis: | The fixed orthodontic appliance consists of brackets that are bonded to the teeth. When the wire is engaged in the slot of the brackets, it generates forces for orthodontic tooth movement. The change in periodontal blood supply provides a biological response which leads to remodelling of the alveolar bone and the orthodontic tooth movement. Many variables influencing orthodontic treatment cannot be controlled fully, such as growth and tissue response to appliances. However, the force placed on the tooth should be a controllable variable, and a careful study of the physics underlying clinical applications can help in reducing undesirable side effects. The properties of orthodontic wires such as: strength, stiffness, elasticity and spring-back define their clinical usefulness. The ideal orthodontic wire should exhibit the following properties: large spring-back, low stiffness, good formability, high stored energy, biocompatibility and environmental stability, low surface friction, and the capability of being welded or soldered to auxiliaries. The ideal arch wire has not been introduced yet. Once the wire is activated or bent, it is the unloading or deactivating forces that produce the orthodontic tooth movement. For these reasons, it is necessary to know the force level caused by each individual wire used in orthodontic treatment. Finally, the purpose of this paper is a presentation of force measurements which are generated by different super-elasticity NiTi wires. |
|---|
| Ključne besede: | force measurements, orhodontic system, teeth, NiTi alloys |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Leto izida: | 2013 |
|---|
| Št. strani: | str. 105-122 |
|---|
| Številčenje: | Letn. 61, št. 2 |
|---|
| PID: | 20.500.12556/DKUM-67264  |
|---|
| ISSN: | 0042-8469 |
|---|
| UDK: | 620.1/.2:616.31 |
|---|
| COBISS.SI-ID: | 16932630  |
|---|
| DOI: | 10.5937/vojtehg61-2960  |
|---|
| ISSN pri članku: | 0042-8469 |
|---|
| NUK URN: | URN:SI:UM:DK:XFPWJEIC |
|---|
| Datum objave v DKUM: | 09.08.2017 |
|---|
| Število ogledov: | 1447 |
|---|
| Število prenosov: | 374 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |