| Naslov: | Numerical analysis of a transtibial prosthesis socket using 3D-Printed Bio-Based PLA |
|---|
| Avtorji: | ID Plesec, Vasja (Avtor) ID Humar, Jani (Avtor) ID Dobnik-Dubrovski, Polona (Avtor) ID Harih, Gregor (Avtor) |
| Datoteke: | Plesec-2023-Numerical_Analysis_of_a_Transtibia.pdf (5,99 MB) MD5: F40E361A7212E6AF0DB8E30E86DD1E9E
https://doi.org/10.3390/ma16051985
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Članek v reviji |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FS - Fakulteta za strojništvo
|
|---|
| Opis: | Lower-limb prosthesis design and manufacturing still rely mostly on the workshop process of trial-and-error using expensive unrecyclable composite materials, resulting in time-consuming, material-wasting, and, ultimately, expensive prostheses. Therefore, we investigated the possibility of utilizing Fused Deposition Modeling 3D-printing technology with inexpensive bio-based and bio-degradable Polylactic Acid (PLA) material for prosthesis socket development and manufacturing. The safety and stability of the proposed 3D-printed PLA socket were analyzed using a recently developed generic transtibial numeric model, with boundary conditions of donning and newly developed realistic gait cycle phases of a heel strike and forefoot loading according to ISO 10328. The material properties of the 3D-printed PLA were determined using uniaxial tensile and compression tests on transverse and longitudinal samples. Numerical simulations with all boundary conditions were performed for the 3D-printed PLA and traditional polystyrene check and definitive composite socket. The results showed that the 3D-printed PLA socket withstands the occurring von-Mises stresses of 5.4 MPa and 10.8 MPa under heel strike and push-off gait conditions, respectively. Furthermore, the maximum deformations observed in the 3D-printed PLA socket of 0.74 mm and 2.66 mm were similar to the check socket deformations of 0.67 mm and 2.52 mm during heel strike and push-off, respectively, hence providing the same stability for the amputees. We have shown that an inexpensive, bio-based, and bio-degradable PLA material can be considered for manufacturing the lower-limb prosthesis, resulting in an environmentally friendly and inexpensive solution. |
|---|
| Ključne besede: | 3D printing, bio-based, polylactic acid, PLA, prosthesis, prosthesis socket, numerical model, finite element method |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 25.01.2023 |
|---|
| Datum sprejetja članka: | 24.02.2023 |
|---|
| Datum objave: | 28.02.2023 |
|---|
| Založnik: | MDPI |
|---|
| Leto izida: | 2023 |
|---|
| Št. strani: | Str. 1-17 |
|---|
| Številčenje: | Letn. 16, Št. 5, št. članka 1985 |
|---|
| PID: | 20.500.12556/DKUM-87382  |
|---|
| UDK: | 331.1:519.6 |
|---|
| COBISS.SI-ID: | 144563203  |
|---|
| DOI: | 10.3390/ma16051985  |
|---|
| ISSN pri članku: | 1996-1944 |
|---|
| Datum objave v DKUM: | 14.03.2024 |
|---|
| Število ogledov: | 449 |
|---|
| Število prenosov: | 63 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |