| Naslov: | Dual-modular versus single-modular stems for primary total hip arthroplasty : a long-term survival analysis |
|---|
| Avtorji: | ID Fokter, Samo K. (Avtor) ID Noč, Nejc (Avtor) ID Levašič, Vesna (Avtor) ID Hanc, Marko (Avtor) ID Zajc, Jan (Avtor) |
| Datoteke: | Fokter-2023-Dual-Modular_Versus_Single-Modular.pdf (1,09 MB) MD5: EF6EA837B5125B8684A5FAB871A04079
https://doi.org/10.3390/medicina59020290
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Znanstveno delo |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | MF - Medicinska fakulteta
|
|---|
| Opis: | Background and Objectives: Increased revision rate of dual-modular (DM) femoral stems in primary total hip arthroplasty (THA) because of modular-neck breakage and adverse local tissue reactions (ALTRs) to additional junction damage products is well established and some designs have been recalled from the market. However, some long-term studies of specific DM stems did not confirm the inferiority of these stems compared to standard single-modular (SM) stems, and a head-to-head comparison THA is missing. The objectives of this multicentre study were to determine the survivorship and complication rates of a common DM stem design compared to a similar SM stem. Materials and Methods: In a time frame from January 2012 to November 2015, a cohort of 807 patients (882 hips) consecutively underwent primary cementless THAs at two orthopaedic centres. 377 hips were treated with a Zweimüller-type DM stem THA system and 505 hips with a similar SM stem THA system, both including a modern press-fit acetabulum. Kaplan-Meier survivorship and complication rates were compared between both groups in a median follow-up of 9.0 years (maximum, 9.9 years). Results: The 9-year survivorship of the DM stem THA system (92.6%, 95% CI 89.9–95.3) was significantly lower than that of the SM stem THA system (97.0%, 95% CI 95.2–98.8). There were no differences in revision rates for septic loosening, dislocation, and periprosthetic fractures between the two groups. One ceramic inlay and one Ti-alloy modular neck breakage occurred in the DM stem THA system group, but the main reason for revision in this group was aseptic loosening of components. Conclusions: The survivorship of the DM stem THA system was lower than the similar SM stem THA system in a comparable clinical environment with long-term follow-up. Our results confirmed that no rationale for stem modularity exists in primary THAs. |
|---|
| Ključne besede: | total hip arthroplasty, modular necks, exchangeable necks, survival rate, complications, revision rate, primary hip replacement, prosthesis, Ti-alloy |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 21.12.2022 |
|---|
| Datum sprejetja članka: | 31.01.2023 |
|---|
| Datum objave: | 02.02.2023 |
|---|
| Založnik: | MDPI |
|---|
| Leto izida: | 2023 |
|---|
| Št. strani: | Str. 1-10 |
|---|
| Številčenje: | Letn. 59, Št. 2, št. članka 290 |
|---|
| PID: | 20.500.12556/DKUM-87410  |
|---|
| UDK: | 617.3 |
|---|
| COBISS.SI-ID: | 141004291  |
|---|
| DOI: | 10.3390/medicina59020290  |
|---|
| ISSN pri članku: | 1648-9144 |
|---|
| Datum objave v DKUM: | 18.03.2024 |
|---|
| Število ogledov: | 563 |
|---|
| Število prenosov: | 25 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |