| Naslov: | Potentiometric surfactant sensor with a pt-doped acid-activated multi-walled carbon nanotube-based ionophore nanocomposite |
|---|
| Avtorji: | ID Glumac, Nada (Avtor) ID Momčilović, Milan (Avtor) ID Kramberger, Iztok (Avtor) ID Štraus, Darko (Avtor) ID Sakač, Nikola (Avtor) ID Kovač-Andrić, Elvira (Avtor) ID Đurin, Bojan (Avtor) ID Kraševac Sakač, Marija (Avtor) ID Đambić, Kristina (Avtor) ID Jozanović, Marija (Avtor) |
| Datoteke: | sensors-24-02388.pdf (16,29 MB) MD5: 4EDF4F512556A2FD140DF0EC153F36BE
https://www.mdpi.com/1424-8220/24/8/2388
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Članek v reviji |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FERI - Fakulteta za elektrotehniko, računalništvo in informatiko
|
|---|
| Opis: | Two new surfactant sensors were developed by synthesizing Pt-doped acid-activated multiwalled carbon nanotubes (Pt@MWCNTs). Two different ionophores using Pt@MWCNTs, a new plasticizer, and (a) cationic surfactant 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-DHBI (Pt@MWCNT-DHBI ionophore) and (b) anionic surfactant dodecylbenzenesulfonate-DBS (Pt@MWCNT-DBS ionophore) composites were successfully synthesized and characterized. Both surfactant sensors showed a response to anionic surfactants (dodecylsulfate (SDS) and DBS) and cationic surfactants (cetylpyridinium chloride (CPC) and hexadecyltrimethylammonium bromide (CTAB)). The Pt@MWCNT-DBS sensor showed lower sensitivity than expected with the sub-Nernstian response of ≈23 mV/decade of activity for CPC and CTAB and ≈33 mV/decade of activity for SDS and DBS. The Pt@MWCNTDHBI surfactant sensor had superior response properties, including a Nernstian response to SDS (59.1 mV/decade) and a near-Nernstian response to DBS (57.5 mV/decade), with linear response regions for both anionic surfactants down to ≈2 × 10−6 M. The Pt@MWCNT-DHBI was also useful in critical micellar concentration (CMC) detection. Common anions showed very low interferences with the sensor. The sensor was successfully employed for the potentiometric titration of a technical grade cationic surfactant with good recoveries. The content of cationic surfactants was measured in six samples of complex commercial detergents. The Pt@MWCNT-DHBI surfactant sensor showed good agreement with the ISE surfactant sensor and classical two-phase titration and could be used as an analytical tool in quality control |
|---|
| Ključne besede: | potentiometric surfactant sensor, metal-doped MWCNT, surfactants, carbon nanocomposite, sensors |
|---|
| Poslano v recenzijo: | 10.03.2024 |
|---|
| Datum sprejetja članka: | 08.04.2024 |
|---|
| Datum objave: | 09.04.2024 |
|---|
| Založnik: | MDPI |
|---|
| Leto izida: | 2024 |
|---|
| Št. strani: | 14 str. |
|---|
| Številčenje: | Vol. 24, iss. 8, [article no.] 2388 |
|---|
| PID: | 20.500.12556/DKUM-90157  |
|---|
| UDK: | 681.586 |
|---|
| COBISS.SI-ID: | 192015107  |
|---|
| DOI: | 10.3390/s24082388  |
|---|
| ISSN pri članku: | 1424-8220 |
|---|
| Avtorske pravice: | © 2024 by the authors |
|---|
| Datum objave v DKUM: | 23.08.2024 |
|---|
| Število ogledov: | 300 |
|---|
| Število prenosov: | 39 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |