| Naslov: | Study of a sensitive and selective electrochemical biosensor for glucose based on ▫$Bi_2Ru_2O_7$▫ pyrochlore clusters combined with MWCNTs |
|---|
| Avtorji: | ID Isailović, Jelena (Avtor) ID Dapčević, Aleksandra (Avtor) ID Žunić, Milan (Avtor) ID Finšgar, Matjaž (Avtor) ID Vidović, Kristijan (Avtor) ID Tasić, Nikola (Avtor) ID Hočevar, Samo B. (Avtor) |
| Datoteke: | chemosensors-13-00109-v2.pdf (3,68 MB) MD5: B65D1618A5E8F105DE8CDD1E3E1F421B
https://www.mdpi.com/2227-9040/13/3/109
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Članek v reviji |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FKKT - Fakulteta za kemijo in kemijsko tehnologijo
|
|---|
| Opis: | The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 μM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose. |
|---|
| Ključne besede: | glucose sensor, glucose oxidase, Bi2Ru2O7 pyrochlore, multi-walled carbon nanotubes, voltammetry, serum |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 14.01.2025 |
|---|
| Datum sprejetja članka: | 13.03.2025 |
|---|
| Datum objave: | 15.03.2025 |
|---|
| Založnik: | MDPI |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | 13 str. |
|---|
| Številčenje: | Vol. 13, iss. 3, [article no.] 109 |
|---|
| PID: | 20.500.12556/DKUM-92200  |
|---|
| UDK: | 544 |
|---|
| COBISS.SI-ID: | 229474563  |
|---|
| DOI: | 10.3390/chemosensors13030109  |
|---|
| ISSN pri članku: | 2227-9040 |
|---|
| Avtorske pravice: | © 2025 by the authors |
|---|
| Datum objave v DKUM: | 20.03.2025 |
|---|
| Število ogledov: | 189 |
|---|
| Število prenosov: | 5 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |