| | SLO | ENG | Piškotki in zasebnost

Večja pisava | Manjša pisava

Izpis gradiva Pomoč

Naslov:Corrosion behavior of nickel–titanium continuous-casted alloys
Avtorji:ID Miličić Lazić, Minja (Avtor)
ID Mitić, Dijana (Avtor)
ID Radović, Katarina (Avtor)
ID Djordjević, Igor (Avtor)
ID Majerič, Peter (Avtor)
ID Rudolf, Rebeka (Avtor)
ID Grgur, Branimir (Avtor)
Datoteke:.pdf metals-14-00088.pdf (14,90 MB)
MD5: 0B8CBCA47FDF8F601518FEAE298DA50B
 
URL https://www.mdpi.com/2075-4701/14/1/88
 
Jezik:Angleški jezik
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Opis:Variations in the corrosion behavior of biomedical NiTi alloys in Cl− containing and acidic environments present a problem with their biological implantation. The objective of this research was to evaluate the synergy of the microstructure, the corrosion behavior, and the biocompatibility of novel continuous-cast NiTi alloys and to compare them with commercial NiTi alloys. The two alloys have a practically identical nominal chemical composition, but they differ in production technology. The continuous casting technology involved vacuum induction melting of the basic components and vertical continuous casting, while the commercial NiTi alloy was produced through a process of casting, hot rolling, and forming into square shapes. The microstructure was revealed to determine the surface area and size of grains. The corrosion of a commercial nickel–titanium alloy and one prepared by a novel continuous casting method in acidic and chloride-containing solutions was studied via analytical and electrochemical tests. Localized corrosion characteristics related to oxide properties, when exposed to 9 g L−1 NaCl solution, were examined with focused ion beam analysis and subsequent microchemical analysis of the formed corrosive products. Corrosion potential over time and the oxide film resistance were analyzed using linear polarization measurements. To obtain a preliminary estimate of biocompatibility, human fibroblast cells were used in indirect contact, i.e., alloy conditioning medium. The continuous casting method resulted in a reduction in the average grain size in comparison to the commercial sample and better corrosion stability of the sample in an acidic environment. Also, in a solution of 9 g L−1 NaCl the commercial sample showed high values for the corrosion current density (jcorr = 6 µA cm−2), which indicated low corrosion resistance, while the continuous casting sample possessed much better corrosion stability and lower values for the corrosion current density (jcorr = 0.2 µA cm−2). In line with that, elemental analysis of the corroded surfaces showed higher Cl− ion deposition over the surface layer of the commercial sample, suggesting local oxide breakdown. Moreover, NiTicc reached a value three times higher for polarization resistance (Rp = 270 kΩ cm2) over time in comparison to the commercial sample (Rp~100 kΩ cm2). Biocompatibility evaluation showed that human fibroblast cells exhibited altered metabolic activity. An MTT assay showed that cells’ mitochondrial activity dropped below that of control cells in the presence of both materials’ supernatants.
Ključne besede:nickel–titanium, corosion behaviour, electrochemical testing, NiTi biocompatibility
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Poslano v recenzijo:27.10.2023
Datum sprejetja članka:28.12.2023
Datum objave:11.01.2024
Založnik:MDPI AG
Leto izida:2024
Št. strani:16 str.
Številčenje:Vol. 14, iss. 1, [article no.] 88
PID:20.500.12556/DKUM-93511 Novo okno
UDK:621.833.1:539.4
COBISS.SI-ID:181212163 Novo okno
DOI:10.3390/met14010088 Novo okno
ISSN pri članku:2075-4701
Avtorske pravice:© 2024 by the authors
Datum objave v DKUM:30.06.2025
Število ogledov:172
Število prenosov:11
Metapodatki:XML DC-XML DC-RDF
Področja:Ostalo
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share



Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Metals
Skrajšan naslov:Metals
Založnik:MDPI AG
ISSN:2075-4701
COBISS.SI-ID:15976214 Novo okno

Gradivo je financirano iz projekta

Financer:Drugi - Drug financer ali več financerjev
Naslov:the International Eureka project
Akronim:GOLD-GERE!17091

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:nikel, titan, korozija, elektrokemija, udarna žilavost