Title:SEGREVANJE PROTIEKSPLOZIJSKEGA ASINHRONSKEGA MOTORJA PRI FREKVENCI NAPAJALNE NAPETOSTI 50 IN 60Hz
Authors:ID Gajšek, Boštjan (Author)
ID Hadžiselimović, Miralem (Mentor) More about this mentor... New window
Files:.pdf VS_Gajsek_Bostjan_2009.pdf (2,31 MB)
MD5: 1F825B76AD090E8348BF7011FD869F23
PID: 20.500.12556/dkum/41360f5f-979c-4572-8762-9a5775c38880
 
Language:Slovenian
Work type:Undergraduate thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Cilj diplomske naloge je analizirati delovanje protieksplozijskega motorja pri napajanju 400V/50Hz in s 460V/60Hz. Prehod iz frekvence 50 na 60 Hz pomeni povečanje oddane moči motorja. Posledično se pri obratovanju povečajo izgube, kar vpliva na povišanje temperatur na ohišju motorja, hkrati pa se zaradi višjih vrtljajev rotorja in s tem ventilatorja motor bolje hladi. Koliko vpliva na segrevanje motorja povečanje izgub in koliko se z izboljšanim hlajenjem izgube odvajajo, je analizirano v tem diplomskem delu. Vso delo in meritve smo opravili v Laboratoriju za električne stroje (LABES) na Fakulteti za elektrotehniko, računalništvo in informatiko Univerze v Mariboru.
Keywords:asinhronski motor, protieksplozijska zaščita, izgube moči, temperaturna slika
Place of publishing:Maribor
Publisher:[B. Gajšek]
Year of publishing:2009
PID:20.500.12556/DKUM-12274 New window
UDC:621.313.333.017(043.2)
COBISS.SI-ID:13635094 New window
NUK URN:URN:SI:UM:DK:OOFW5FCR
Publication date in DKUM:05.11.2009
Views:2567
Downloads:227
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:HEATING OF EXPLOSION-PROOF INDUCTION MOTOR AT FREQUENCY OF SUPPLY VOLTAGE 50 AND 60Hz
Abstract:Diploma work presents the heating analysis of explosion – proof induction motor. It focuses on the comparison of motor temperature rise when the motor is fed with a different supply voltage/frequency ratio (i.e. 400V/50Hz and 460V/60Hz). The transition of supply voltage frequency from 50 Hz to 60 Hz results in an increase of mechanical output power proportional to the frequency increase. However, it also results in an increase of power losses. The presented results show the feasibility of using explosion-protected fan-cooled induction motors with both, 50 and 60 Hz supply frequency because of the improved heat transfer at 60 Hz. In the case of non-ventilated explosion-proof induction motors presented results show the feasibility of using the same motor for supply frequency 50 and 60 Hz but at the same output power. The work was conducted in the Laboratory for electrical machines at the Faculty of Electrical Engineering and Computer Science.
Keywords:induction motor, explosion - proof motors, power losses, temperature.