Title:UPORABA SKOZNJIKOV V DISTRIBUCIJSKEM OMREŽJU
Authors:ID Črešnik, Tadej (Author)
ID Pihler, Jože (Mentor) More about this mentor... New window
ID Voršič, Jože (Comentor)
Files:.pdf UNI_Cresnik_Tadej_2011.pdf (3,20 MB)
MD5: 1016B5864AB9BF25C4729151D04BFC31
PID: 20.500.12556/dkum/e4b3f1e3-0bd4-4c71-aa3b-a73e821f8439
 
Language:Slovenian
Work type:Undergraduate thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Namen diplomske naloge je bil raziskati problematiko pri uporabi skoznjikov v distribucijskem omrežju in narediti kosovni preskus na 24 kV ameriških skoznjikih proizvajalca Piedmont Dielectrics Corporation. Preskusi so bili izvedeni na neuporabljenih skoznjikih in na tistih, ki so obratovali deset let. Opisani so tudi postopki za preskušanje srednjenapetostnih skoznjikov in merilna proga za meritev delnih praznitev. Vse meritve so bile izvedene v Infrastrukturnem centru za izvajanje energetskih meritev – ICEM, ki se nahaja ob elektrarni Mariborski otok.
Keywords:skoznjik, okvare, delne praznitve
Place of publishing:Maribor
Publisher:[T. Črešnik]
Year of publishing:2011
PID:20.500.12556/DKUM-18078 New window
UDC:621.315.626(043.2)
COBISS.SI-ID:15120918 New window
NUK URN:URN:SI:UM:DK:GFITZVMJ
Publication date in DKUM:13.04.2011
Views:2401
Downloads:205
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:USE OF BUSHINGS IN DISTRIBUTION ELECTRICAL POWER SYSTEM
Abstract:The purpose of this diploma thesis was to investigate the problems with the use of bushings in distribution electrical power system and to make regular test on 24 kV bushings, designed and manufactured in United States of America by Piedmont Dielectrics Corporation. The tests were performed on the unused and the ten-year-old bushings. I have described the test procedures for medium voltage bushings and the test circuit for partial discharges. All measurements were made in Infrastructural Centre for Energy Measurements – ICEM, which is placed next to the power station Mariborski otok.
Keywords:bushing, failure, partial discharge