Title:TEMPERATURA VODNIKA DALJNOVODA V ODVISNOSTI OD TOKOVNE OBREMENITVE IN VPLIVA OKOLJA
Authors:ID Deželak, Damjan (Author)
ID Štumberger, Gorazd (Mentor) More about this mentor... New window
Files:.pdf UNI_Dezelak_Damjan_2011.pdf (1,31 MB)
MD5: 2C272BD587CD46D6A6347FEBBD45651F
PID: 20.500.12556/dkum/afdba1eb-7478-4120-8764-79cf645cd47e
 
Language:Slovenian
Work type:Undergraduate thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V Slovenskem elektroenergetskem sistemu se za prenos električne energije v 400 kV omrežju uporablja vodnik Al/Je 490/65. Temperatura uporabljenega vodnika daljnovoda v obratovanju predstavlja enega izmed osnovnih mejnih pogojev za obratovanje daljnovoda. Dopustno segrevanje namreč ne sme preseči dovoljene vrednosti, ker vpliva na poslabšanje mehanskih lastnosti vodnika in povese. V diplomski nalogi je teoretično raziskana možnost povečanja tokovne obremenitve daljnovoda glede na spreminjanje zunanjih dejavnikov in sicer temperature okolice, vetra in sonca. Osredotočili smo se predvsem na ugotovitve CIGRE, ki so upoštevane v izračunih v programskem paketu MATLAB.
Keywords:elektroenergetski sistemi, daljnovod, temperatura vodnika, poves vodnika
Place of publishing:[Maribor
Publisher:D. Deželak
Year of publishing:2011
PID:20.500.12556/DKUM-18533 New window
UDC:621.315.1(043.2)
COBISS.SI-ID:15206422 New window
NUK URN:URN:SI:UM:DK:I1RQQEGT
Publication date in DKUM:17.05.2011
Views:3226
Downloads:498
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:OVERHEAD POWER LINE CONDUCTOR TEMPERATURE DEPENDING ON CURRENT LOADING AND ENVIRONMENTAL IMPACTS
Abstract:In the Slovenian 400 kV power system the conductor Al/Fe 490/65 is used for the transmission of electricity. Temperature of the overhead power line conductor during operation represents one of the basic operational limitation parameters for the overhead power line. Because of the negative impact on the mechanical parameters of the conductor and conductor sagging the conductor temperature must be under prescribed limits. Apart from that, the external parameters like ambient temperature, wind and solar radiation could influenced the conductor temperature. In this work the theoretical study of the possibility in the increasing current loading of the conductor, considering aforementioned external factors, is investigated. Mainly the findings of CIGRE working group are applied in the MATLAB program.
Keywords:power systems, overhead power line, conductor temperature, conductor sagging