Abstract: Predmet magistrskega dela je analiza temperaturnih razmer v industrijskih prostorih, kjer imamo večje izvore toplote. Podan je osnovni koncept reševanja težav z visokimi temperaturami v prostorih, kjer imamo stalne izvore toplote. V našem primeru imamo na razpolago veliko nizkotlačne pare, zato smo za odvod presežkov toplote izbrali absorpcijsko hladilno napravo. V potrditev, da imamo presežke toplote v prostorih IB107 smo izdelali dinamični model prostorov, ki natančneje prikazuje lokacije s presežki toplote.
Keywords:prenos toplote, izračun izgub toplote, izračun izvorov toplote, dinamični model prostora, absorpcijska hladilna naprava.
Place of publishing:Krško
Publisher:[I. Franko]
Year of publishing:2011
PID:20.500.12556/DKUM-19532 New window
UDC:621.56.047(043.3)
COBISS.SI-ID:1024056668 New window
NUK URN:URN:SI:UM:DK:TNKXHM8P
Publication date in DKUM:23.08.2011
Views:3398
Downloads:252
Metadata:XML DC-XML DC-RDF
Categories:FE
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:DYNAMICAL MODEL OF ABSORPTION REFRIGERATION SYSTEM
Abstract: Master's thesis analyses the temperature conditions in industrial premises, where we have substantial sources of heat. The paper represents the basic concept of solving problems with high temperatures in facilities where we have permanent sources of heat. In our case we have huge amounts of low-pressure steam, that is why we chose the absorption chiller for outlet of waste heat. To confirm that we have a surplus of heat in rooms IB107 we created a dynamic model of the premises, which accurately shows the locations of surplus heat.
Keywords:heat transfer, calculation of heat loss, calculation of heat sources, dynamic model of room, absorption chiller.