Title:REKONSTRUKCIJA TRANSFORMATORSKE POSTAJE GOLNIK
Authors:ID Dedić, Elvedin (Author)
ID Štumberger, Gorazd (Mentor) More about this mentor... New window
ID Štumberger, Bojan (Comentor)
Files:.pdf VS_Dedic_Elvedin_2012.pdf (1,51 MB)
MD5: E91837D64C3D5C9989B148F13E7A6B8B
PID: 20.500.12556/dkum/4149f87c-a230-4fca-a2be-5c4d1a99eace
 
Language:Slovenian
Work type:Bachelor thesis/paper
Organization:FE - Faculty of Energy Technology
Abstract:Diplomska naloga opisuje izdelavo načrta za rekonstrukcijo transformatorske postaje v Bolnišnici Golnik – Kopa. Obstoječa transformatorska postaja se rekonstruira in nadomesti z novo v obstoječem objektu – na isti lokaciji. V transformatorski postaji bosta vgrajena dva transformatorja TR1 in TR2, vsak po 1000 kVA moči. Transformator TR1 bo napajal obstoječe porabnike, medtem ko bo transformator TR2 rezerva. Za vključitev v zanko se uporabi obstoječe 20 kV vode. Prav tako se uporabi tudi obstoječe NN vode za priključitev obstoječih porabnikov. Transformatorska postaja mora imeti zagotovljen 24-urni dostop za elektro distributerja.
Keywords:Transformatorska postaja, rekonstrukcija
Place of publishing:Velenje
Publisher:[E. Dedić]
Year of publishing:2011
PID:20.500.12556/DKUM-22095 New window
UDC:621.311.42(043.2)
COBISS.SI-ID:1024080220 New window
NUK URN:URN:SI:UM:DK:EXH7T9HQ
Publication date in DKUM:21.03.2012
Views:4467
Downloads:445
Metadata:XML DC-XML DC-RDF
Categories:FE
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:RECONSTRUCTION OF TRANSFORMER SUBSTATION GOLNIK
Abstract:The diploma thesis describes the preparation of the technical documentation for the reconstruction of transformer station in Hospital Golnik – Kopa. The existing transformer station is planned to be reconstructed and replaced with the new one in an existing facility on the same location. In transformer station two transformers TR1 and TR2 will be installed, each of 1000 kVA power. Transformer TR1 will provide power for existing customers, while the transformer TR2 will serve as reserve. For inclusion in the loop the existing 20 kV line will be used. The existing LV infrastructure will be used to connect existing customers. Transformer station must provide 24-hour access for the electrical distributor
Keywords:Transformer substation, reconstruction