| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Tungsten - tungsten trioxide electrodes for the long-term monitoring of corrosion processes in highly alkaline media and concrete-based materials
Authors:ID Kolar, Mitja (Author)
ID Doliška, Aleš (Author)
ID Švegl, Franc (Author)
ID Kalcher, Kurt (Author)
Files:.pdf Acta_Chimica_Slovenica_2010_Kolar_et_al._Tungsten_-_tungsten_trioxide_electrodes_for_the_long-term_monitoring_of_corrosion_processes_in.pdf (1,67 MB)
MD5: 67A8D5FA5990FC0E07E33B50054174A9
PID: 20.500.12556/dkum/fa792d19-93e7-4421-ae35-162e4525f534
 
URL http://acta-arhiv.chem-soc.si/57/57-4-813.pdf
 
Language:English
Work type:Scientific work
Typology:1.01 - Original Scientific Article
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:The determination of pH in highly alkaline solutions and concrete materials is extremely important for monitoring or predicting the corrosion processes of reinforced concrete structures and to follow the hydration process of Portland cement, fly-ash, micro silica and other materials used in concrete manufacturing. The corrosion of reinforced concrete structures and the hydration of pozzolanic materials are long-term processes, which means, that appropriate durable, and resilient pH electrodes are needed, for direct implantation regarding solid concrete bodies. The purpose of this work was to characterise the potentiometric and surface properties of tungsten electrodes after exposure to extreme alkaline solutions. The tungsten wire surface was activated at 800 °C for 30 min within an oxygen flow. The formation of homogenous and compact multiple layers of $WO_3$ crystals was observed using X-ray diffraction and scanning electron microscopy. X-ray diffraction of thosetungsten electrodes exposed to saturated calcium hydroxide solution or the pore-water of cement-based materials during 10 months, indicated partly dissolved $WO_3$. Two new compounds appeared on the electrodes surfaces; pure tungsten and $CaWO_4$. The presence of tungsten was affecting any potentiometric response in acidic pH region (2-5) but in pH 5-12 region the response still remained linear with a slope of 42 2 mV/pH unit. The $W/WO_3$ electrode was suitable for the long-term monitoring of corrosion processes in concrete-basedmaterials according to the pH changes as it has stable and repeatable responses to alkaline solutions (pH > 12). All the tested interferring ions had no significant influence on electrode potential. The $W/WO_3$ electrode is simple, robust, inexpensive, and temperature resistant and can be applied in potentiometric titrations as well as in batch and flow-injection analysis. The prepared electrode is a highly promising pH sensor for the monitoring of pH changes in highly alkaline capillary water of concrete.
Keywords:potentiometry, pH, tungsten - tungsten trioxide, pore water, concrete, flow-injection analysis
Publication status:Published
Publication version:Version of Record
Year of publishing:2010
Number of pages:str. 813-820
Numbering:Letn. 57, št. 4
PID:20.500.12556/DKUM-26719 New window
ISSN:1318-0207
UDC:543.5:691
ISSN on article:1318-0207
COBISS.SI-ID:14701078 New window
NUK URN:URN:SI:UM:DK:PUZTRJQG
Publication date in DKUM:31.05.2012
Views:2749
Downloads:139
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Acta Chimica Slovenica
Shortened title:Acta Chim. Slov.
Publisher:Slovensko kemijsko društvo
ISSN:1318-0207
COBISS.SI-ID:14086149 New window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Licensing start date:31.05.2012

Secondary language

Language:Slovenian
Abstract:Merjenje pH v močno alkalnih raztopinah in v betonskih vzorcih je zelo pomembno za napoved korozije armature, kakor tudi za spremljanje drugih hidratacijskih procesov materialov, ki se uporabljajo pri proizvodnji betona. Tovrstni procesi so dologotrajni in zahtevajo robustne, vzdržljive in enostavne pH senzorje, ki omogočajo tudi neposredno namestitev v betonsko matriko. V delu so predstavljene $W/WO_3$ elektrode, ki so bile aktivirane pri 800 °C za 30 minut, pri čemer je na površini nastala homogena in stabilna plast $WO_3$. Tudi dolgotrajna, 10 mesečna izpostavitev v nasičeni raztopini $Ca(OH)_2$, kaže na nespremenjene potenciometrične lastnosti elektrod v območju med pH 5 in 12 z naklonom 42 ± 2 mV/pH. Preizkušeni interferenčni ioni niso imeli signifikantnega vpliva na elektrodni potencial. $W/WO_3$ elektrode so se izkazale kot enostaven, dostopen, temperaturno obstojen in obetaven pH senzor, ki ga lahko uporabljamo tako za klasične potenciometrične titracije kot meritve v pretoku. Še posebej $W/WO_3$ elektrode odlikuje dobro ponovljiv odziv v močno alkalnih raztopinah (pH > 12), kar nakazuje uporabo pri določanju pH vrednosti kapilarne vode ter in-situ meritvah v betonu.
Keywords:potenciometrija, pH, volframov trioksid


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica