| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Implementing hygiene monitoring systems in hospital laundries in order to reduce microbial contamination of hospital textiles
Authors:ID Fijan, Sabina (Author)
ID Šostar-Turk, Sonja (Author)
ID Cencič, Avrelija (Author)
Files:URL http://dx.doi.org/10.1016/j.jhin.2005.02.005
 
Language:English
Work type:Unknown
Typology:1.01 - Original Scientific Article
Organization:FS - Faculty of Mechanical Engineering
Abstract:As textiles sent to hospital laundries contain many types of pathogenic organisms, it is important that laundering not only has an appropriate cleaning effect but also has a satisfactory disinfecting effect. Critical to this process is the maintenance of an appropriate hygiene level in the clean area of laundries in order to prevent recontamination of textiles from manual handling when ironing, folding, packing etc. The aims of this study were to evaluate the hygienic state of a hospital laundry, to introduce continuous sanitary measures, and to introduce a continuous hygiene monitoring system with an infection control programme. Two systems for evaluating hospital laundry hygiene were combined: HACCP principles (hazard analysis and critical control points) and RAL-GZ 992 standards (quality assurance standard for textile care of hospital laundry). Evaluation of the hygienic state of the hospital laundry was carried out by evaluating the number and types of micro-organisms present at the critical control points throughout the whole laundering process, using RODAC agar plates for surface sampling and the pour plate method for investigating water samples. The initial examination showed that the sanitary condition of the laundry did not reach the required hygiene level. Therefore, fundamental sanitation measures were instituted and the examination was repeated. Results were then satisfactory. The most important critical control point was the chemothermal laundering efficiency of the laundering process. To prevent micro-organisms spreading into the entire cleanworking area, it is important that, in addition to regular sanitary measures such as cleaning/disinfecting all working areas, technical equipment and storage shelves etc., regular education sessions for laundry employees on proper hand hygiene is undertaken and effective separation of the clean and dirty working areas is achieved.
Keywords:textile care, hospital laundry, laundry hygiene, micro-organisms, washing quality parameters, sanitary microbiological parameters, hospital-acquired disease prevention, sanitary measures
Year of publishing:2005
PID:20.500.12556/DKUM-27030 New window
UDC:677.07:648.23:613
ISSN on article:0195-6701
COBISS.SI-ID:9640982 New window
NUK URN:URN:SI:UM:DK:2QUHAPNA
Publication date in DKUM:01.06.2012
Views:3132
Downloads:102
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:The Journal of hospital infection
Shortened title:J. hosp. infect.
Publisher:Academic Press.
ISSN:0195-6701
COBISS.SI-ID:6404871 New window

Secondary language

Language:English
Keywords:nega tekstilij, bolnišnično perilo, higiena pralnic, mikroorganizmi, kakovostni parametri pranja, sanitarno-mikrobiološki parametri


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica