Title:IMPLEMENTACIJA PLETIZMOGRAFA Z ANALOGNIM LINIJSKIM SENZORJEM
Authors:ID Jesenko, David (Author)
ID Cigale, Boris (Mentor) More about this mentor... New window
Files:.pdf UNI_Jesenko_David_2012.pdf (2,12 MB)
MD5: 84C65E554884E26D0A62566EB49612A7
PID: 20.500.12556/dkum/17ab064d-11ba-426a-8f2c-ffc3f36df81d
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V diplomskem delu predstavimo izvedbo pletizmografa s pomočjo analognega linijskega senzorja. Uporabljen svetlobni senzor vsebuje 1536 fotodiod. V delu opišemo uspešno načrtovanje in praktično izvedbo elektronskega vezja, izdelavo programske opreme za mikrokrmilnik in uporabniškega programa na računalniku za prikaz dobljenih rezultatov. Po primerjavi dobljenih rezultatov z rezultati EKG naprave ugotovimo, da je senzor primeren za takšno uporabo.
Keywords:pletizmograf, linijski senzor, srčni utrip
Place of publishing:Maribor
Publisher:[D. Jesenko]
Year of publishing:2012
PID:20.500.12556/DKUM-38019 New window
UDC:681.527.74.08(043.2)
COBISS.SI-ID:16522262 New window
NUK URN:URN:SI:UM:DK:VBZPOJE4
Publication date in DKUM:16.11.2012
Views:2670
Downloads:191
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:IMPLEMENTATIONOF THE PLETHYSMOGRAPH WITH ANALOG LINE SENSOR
Abstract:The diploma thesis presents the implementation of the plethysmograph with the help of an analogue line sensor. The light sensor that was used consisted of 1536 photodiodes. The thesis also describes the successful design and practical implementation of the electronic circuits, and the making of the software for the microcontroller and the application program on the computer, with the help of which we can display the obtained results. After comparing the gained results of the ECG device, we come to the conclusion that the sensor is suitable for such usage.
Keywords:pletysmograph, line sensor, pulse