Organization:FKBV - Faculty of Agriculture and Life Sciences
Abstract:Na prašičerejski kmetiji Osterc (Vučja vas) smo ugotavljali vpliv podtlačnega prezračevalnega sistema UNITHERM 6.3E na kakovost zraka v vzrejališču, kjer so bili vhlevljeni tekači starosti od 5 do 12 tednov. V poskusu smo pri različnih hitrostih ventilatorja (0,18; 0,27; 0,34 in 0,47 ms-1) merili podatke o količini plinov (O2, CO2, NH3 in H2S) na 24 različnih mestih v prostoru s površino 35,96 m2 in volumnom 86 m3, da bi ugotovili, ali vsebnost plinov ustreza zakonskim predpisom. Merilna mesta so bila na višini 5 in 66 cm od tal v sedmih boksih in na hodniku. Ugotovili smo, da so pri tleh in v kotih vzrejališča najslabši mikroklimatski pogoji. Izmerjene vsebnosti NH3 (4,12 ± 1,5 ppm) in CO2 (851,03 ± 121,2 ppm) so bile največje pri najnižji hitrosti ventilatorja (0,18 ms-1). Večji hitrosti (0,34 in 0,47 ms-1) sta omogočili, da smo s podtlakom dovedli dovolj svežega zraka. Ugotovili smo, da je v opazovanem hlevu za zadostno kroženje zraka en podtlačni ventilator premalo. Dva ventilatorja bi bila idealna rešitev, saj bi lahko delovala pri nižjih hitrostih in hkrati porabila manj električne energije. Na ta način bi bilo omogočeno enakomerno zračenje in boljša sestava zraka v vseh delih vzrejališča, kar bi zagotavljalo pujskom v obdobju predpitanja enake življenjske pogoje. Hkrati bi pa se povečala možnost večjega izkoristka krme in posledično prirast živali.
Keywords:hlev, ventilator, pujski, sestava plinov, amonijak
Place of publishing:Maribor
Year of publishing:2013
PID:20.500.12556/DKUM-42287 New window
NUK URN:URN:SI:UM:DK:QACCRWY2
Publication date in DKUM:15.10.2013
Views:1976
Downloads:118
Metadata:XML DC-XML DC-RDF
Categories:FKBV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:The use of vacuum system for climate regulation in pre-fettering
Abstract:measurements of concentrations of gasses (O2, CO2, NH3, and H2S) at varying airflows (0,18, 0,27, 0,34, and 0,47 ms-1) in 24 different areas inside a room with the area of 35,96 m2 and volume of 86 m3 to evaluate compliance with legal exposure limits. Measurement locations were either 5 cm or 66 cm above ground in the seven pens and the corridor. The microclimate was found to be least optimal near the ground and in the corners. The measured NH3 (4,12 ± 1,5 ppm) and CO2 (851,03 ± 121,2 ppm) concentrations were highest at the lowest ventilator speed (0,18 ms-1). Higher speeds (0,34 or 0,47 ms-1) were sufficient to establish a satisfactory ventilation. The results for the examined farm show only one vacuum fan to be insufficient for satisfactory air circulation. Two fans would be ideal, since they could work at lower speeds and thus use less energy. This would allow for consistent ventilation and better air quality in all parts of the facility, giving all piglets identical living conditions. The resulting stress reduction should improve the health of the animals while simultaneously increasing the efficiency of feeding and growth.