Title:ENERGETSKA SANACIJA STANOVANJSKE HIŠE IZGRAJENE LETA 1933
Authors:ID Brajar, Matjaž (Author)
ID Praunseis, Zdravko (Mentor) More about this mentor... New window
ID Avsec, Jurij (Comentor)
Files:.pdf VS_Brajar_Matjaz_2013.pdf (1,98 MB)
MD5: 586BAAAE65CE9A3F656B6543475FA15F
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Energy Technology
Abstract:Namen diplomske naloge je prikazati celovitost reševanja energetske učinkovitosti stavbe, ki temelji na veljavni zakonodaji. Nazorno in slikovito so opisani materiali ter sistemi konstrukcij toplotnega ovoja, ki zadostijo strogim kriterijem predpisov. Prav tako so prikazani in klasificirani obnovljivi viri energij ter tehnične rešitve, ki so predlagane za obravnavani objekt. Z izračuni je dokazano, da so vse izračunane vrednosti energetskih kazalcev manjše od predpisanih, tako da lahko potrdimo, da je energetsko prenovljena starejša lesena hiša energetsko učinkovit objekt, ki bo lastniku nudil topel in udoben dom brez večjih stroškov za delovanje stavbe.
Keywords:energetska učinkovitost, toplotne izgube, izkoriščanje prostorov
Place of publishing:Krško
Publisher:[M. Brajar]
Year of publishing:2013
PID:20.500.12556/DKUM-42733 New window
UDC:620.9:699.8:728.3-035.3(043.2)
COBISS.SI-ID:1024148316 New window
NUK URN:URN:SI:UM:DK:ZVFKQZOW
Publication date in DKUM:14.10.2013
Views:2107
Downloads:261
Metadata:XML DC-XML DC-RDF
Categories:FE
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:ENERGY SANITATION OF TENEMENT HOUSE BUILT IN YEAR 1933
Abstract:The purpose of this diploma thesis is to introduce how energy efficiency of a building can be completely solved based on applicable legislation. All the materials and the systems of thermal sleeve constructions which satisfy very strict regulations are presented thoroughly and in pictures. The thesis also illustrates and classifies renewable energy sources and technical solutions that are suggested for the object presented. The calculations show that all calculated shares of energy indicators are lower than those regulated. It can be confirmed that an energetically renewed old wooden house is an energy efficient object that would provide a warm and comfortable home for his owner without bigger costs for running the house.