Title:HLAJENJE RAČUNALNIKA
Authors:ID Biščič, Elvis (Author)
ID Solar, Mitja (Mentor) More about this mentor... New window
Files:.pdf VS_Biscic_Elvis_2014.pdf (5,74 MB)
MD5: E8B77C9B341404E35CE40160134A0869
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Namen diplomske naloge je izdelati hladilni sistem, krmiljen z operacijskimi ojačevalniki. Sistem je vseboval štiri temperaturne senzorje, s katerimi smo merili temperaturo. Na osnovi te temperature smo krmilili hitrost vrtenja ventilatorjev. Tako smo omogočili tišje delovanje računalnika ob manjših obremenitvah in boljše hlajenje ob visokih obremenitvah. Temperaturni senzorji so bili nameščeni na procesor, pomnilnik, grafično kartico in trdi disk. Temperaturna senzorja iz procesorja in pomnilnika sta bila priključena na vezje, ki je krmililo en vpihovalni in izpihovalni ventilator. Temperaturna senzorja iz grafične kartice in trdega diska sta bila priključena na drugo vezje, ki je krmililo drugi vpihovalni in izpihovalni ventilator.
Keywords:krmiljeno hlajenje, operacijski ojačevalnik, temperaturni senzor
Place of publishing:Maribor
Publisher:[E. Biščič]
Year of publishing:2014
PID:20.500.12556/DKUM-43429 New window
UDC:004.3´124:681.586.6(043.2)
COBISS.SI-ID:17712406 New window
NUK URN:URN:SI:UM:DK:R6S2KVBP
Publication date in DKUM:05.02.2014
Views:2915
Downloads:355
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:COMPUTER COOLING
Abstract:The purpose of diploma thesis was to produce cooling system controlled by operational amplifiers. The system included four temperature sensors with which, we measured the temperature and on the basis of this temperature was fed the rotational speed of the fans. So we acquired the computer to run quieter at low loads and better cooling at high loads. Temperature sensors were installed at: processor, memory, graphics card and hard drive. Temperature sensor from CPU and memory, have been connected to the circuit, that controls one blow in and blow out fan and the temperature sensor from the graphics card and hard drive to another circuit that controls the other blow in and blow out fan.
Keywords:controlled cooling, operational amplifier, temperature sensor