| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:ZAŠČITA GENERATORJA V NEK
Authors:ID Judež, Damjan (Author)
ID Polajžer, Boštjan (Mentor) More about this mentor... New window
Files:.pdf VS_Judez_Damjan_2014.pdf (3,04 MB)
MD5: 2941D93936EF8DE25CFE737DD4A12FEE
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Diplomska naloga zajema splošni opis elektrarne, proizvodnjo električne energije in relejne zaščite sinhronskega generatorja v Nuklearni elektrarni Krško. V delu so podani posamezni izračuni primarnih in sekundarnih vrednosti parametrov, ki so se uporabili za parametriranje zaščitnih funkcij. Cilj diplomske naloge je bil podrobneje preučiti zaščito in nova spoznanja implementirati v vzdrževalne postopke po katerih preizkušamo relejno zaščito v elektrarni. Sekundarni preizkusi zaščitnih funkcij so bili izvedeni na rezervnem releju, v laboratoriju elektro-vzdrževanja s preizkuševalno napravo Omicron.
Keywords:elektroenergetika, zaščita, sinhronski generator, rele…
Place of publishing:Maribor
Publisher:[D. Judež]
Year of publishing:2014
PID:20.500.12556/DKUM-44635 New window
UDC:621.313.322(043.2)
COBISS.SI-ID:17997334 New window
NUK URN:URN:SI:UM:DK:MGKPCZ5U
Publication date in DKUM:26.06.2014
Views:1730
Downloads:285
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:PROTECTION OF THE GENERATOR IN KRŠKO NPP
Abstract:A thesis includes general description of power plant, the main electric power generation and relay protection of synchronous generator in Krško Nuclear Power Plant. Individual calculations of primary and secondary values of parameters where passed within work, which were used for parameterization of protective functions. The purpose of the thesis was to examine in detail the protection and implement new knowledge in maintenance procedures by which numerical relays where tested in power plant. Secondary testing of protective functions have been implemented on the backup relay in laboratory of electrical maintenance department with the Omicron testing device.
Keywords:power engineering, protection, synchronous generator, relay…


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica