Title:NADGRADNJA ČRPALIŠČA HLADILNE VODE V PODJETJU GKN DRIVELINE ZREČE
Authors:ID Kovač, Uroš (Author)
ID Hace, Aleš (Mentor) More about this mentor... New window
ID Gotlih, Karl (Mentor) More about this mentor... New window
Files:.pdf MAG_Kovac_Uros_2014.pdf (6,51 MB)
MD5: E433D21C9FAD842AC43B2F4B5DE10176
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V okviru magistrske naloge je v celoti analiziran in nadgrajen tehnološki sistem črpališča hladilne vode. V nalogi so opisani in analizirani toplotni izmenjevalci, hladilni stolpi, distribucija hladilne vode ter krmilje sistema proizvajalca Siemens. V osnovi je opisana nadgradnja krmilja črpališča, podrobneje pa so opisane dislocirane meritve temperatur in tlaka ter Siemensove komponente, ki so potrebne za realizacijo meritev. Skozi nalogo je opisan potek realizacije rešitve danega problema nadgradnje črpališča. Projekt je izveden in deluje po zahtevah naročnika.
Keywords:črpališče, hladilna voda, toplotni izmenjevalci, hladilni stolp, SIMATIC ET 200S
Place of publishing:Maribor
Publisher:[U. Kovač]
Year of publishing:2014
PID:20.500.12556/DKUM-46165 New window
UDC:004.312.466:681.51(043.2)
COBISS.SI-ID:18538518 New window
NUK URN:URN:SI:UM:DK:W4DEEW5R
Publication date in DKUM:25.02.2015
Views:1779
Downloads:272
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:UPGRADING THE PUMPING STATION OF COOLING WATER IN THE COMPANY GKN DRIVELINE ZREČE
Abstract:In the context of the master's thesis, the cooling water-pumping technological system is thoroughly analyzed and upgraded. The thesis describes and analyzes the heat exchangers, cooling towers, cooling water distribution and Siemens’ control system. The basis of the thesis is the upgrade of the field control system; the dislocated measurements of temperature and pressure, as the essential Siemens’ measurement realization methods, are particularized in the detailed part of the thesis. The process of realization of the answer to the given field-pump upgrade problem is described throughout the assignment. The project was successfully executed and is now working on the customers set requirements.
Keywords:pumping station, cooling water, heat exchanger, cooling tower, SIMATIC ET 200S