Title:VPLIV ELEKTRIČNEGA OMREŽJA NA DELOVANJE PRENAPETOSTNE ZAŠČITE
Authors:ID Kolbl, Aleš (Author)
ID Pihler, Jože (Mentor) More about this mentor... New window
ID Ribič, Janez (Comentor)
Files:.pdf MAG_Kolbl_Ales_2015.pdf (9,06 MB)
MD5: 4845B483637EC7FA68831A2FA3ABEE38
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V magistrskem delu je opisan postopek izbire in delovanje notranje ter zunanje prenapetostne zaščite. Podrobno je predstavljen izvor strele in ostalih prenapetosti, ki se pojavljajo v okolici ali v samih objektih. Cilj magistrske naloge je, s pomočjo simulacij v programskem paketu Matlab/Simulink, ugotoviti vpliv parametrov kabla v električnih inštalacijah, na delovanje prenapetostne zaščite. Simulacije so se izvajale za realen primer, na razdalji od transformatorske postaje do porabnika. Simulacije so bile opravljene za primere brez prenapetostne zaščite, za primere z eno vrsto prenapetostne zaščite (plinski odvodnik oz. metal-oksidni varistor) in za primer uporabe obeh prenapetostnih zaščit.
Keywords:prenapetostna zaščita, dolžina vodnikov, prenapetosti
Place of publishing:Maribor
Publisher:[A. Kolbl]
Year of publishing:2015
PID:20.500.12556/DKUM-47435 New window
UDC:621.311.1:621.316.91(043.2)
COBISS.SI-ID:18775318 New window
NUK URN:URN:SI:UM:DK:5XLZKHED
Publication date in DKUM:22.05.2015
Views:1585
Downloads:193
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:INFLUENCE OF ELECTRICAL NETWORK TO OVERVOLTAGE PROTECTION OPERATION
Abstract:This master's thesis presents the process of selection as well as functioning of internal and external overvoltage protection. The origin of lightning and other forms of overvoltage, which are emerging in surrounding areas or within facilities themselves, are presented in detail. The purpose of this master's thesis is, with the help of simulations in programme package Matlab/Simulink, to find out the influence of cable parameters in electrical installations on the functioning of overvoltage protection. Simulations have been conducted for a real example, at a distance from the transformer station to the user. Simulations have been carried out for examples without overvoltage protection, for examples with only one kind of overvoltage protection (gas arrester or metal-oxide varistor) as well as for examples with the use of both overvoltage protections.