| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:AKTIVACIJE KLINIČNIH ALARMOV V PROSTORIH OPERACIJSKEGA BLOKA
Authors:ID Ciglar, Ksenija (Author)
ID Križmarić, Miljenko (Mentor) More about this mentor... New window
ID Mekiš, Dušan (Comentor)
Files:.pdf MAG_Ciglar_Ksenija_2015.pdf (2,22 MB)
MD5: C5BB10EEFD939BA9546DA2EDD4816B39
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Dobro izveden sistem kliničnih alarmov lahko reši pacientovo življenje, kajti ti so na prvem mestu glede vzrokov smrti, povezanih z medicinsko tehnologijo. V magistrskem delu smo opisali pomembnost kliničnih alarmov in predstavili, kako so ti alarmi kategorizirani (prioritete). Raziskali smo čase proženja alarmov na kliničnem monitorju Dräger Infinity Gamma. Za simuliranje hemodinamičnih spremenljivk smo uporabili simulatorja elektrokardiografskih (EKG) ritmov Simulaids in HeartSim 200. V kvantitativni raziskavi smo primerjali aktivacije alarmov v dveh različnih skupinah, poimenovanih kritični alarmi in nekritični alarmi. Omejili smo se na hemodinamične parametre, izmerjene z monitorjem Dräger Infinity Gamma. Ugotovili smo, da se alarmi kritične skupine prožijo v povprečju v 4,37 ± 0,16 sekunde, alarmi nekritične skupine pa v 8,51 ± 0,92 sekunde. Primerjali smo tudi časovno prožitev alarmov med hitro in počasno ventrikularno tahikardijo (VT fast in VT slow). Alarm pri VT fast se sproži v povprečju v 3,32 ± 0,28 sekunde, kar je hitreje kot pa pri VT slow, kjer čas proženja alarma znaša 5,88 ± 0,18 sekunde. Simulatorji so sposobni prožiti alarme obeh skupin in jih klinični monitor tudi prepozna ter signalizira z alarmom.
Keywords:alarmi, klinični monitor, simulacije, hemodinamski monitoring.
Place of publishing:Maribor
Publisher:[K. Ciglar]
Year of publishing:2015
PID:20.500.12556/DKUM-48330 New window
UDC:615.47(043.2)
COBISS.SI-ID:2125732 New window
NUK URN:URN:SI:UM:DK:MOF6WNU7
Publication date in DKUM:13.07.2015
Views:1487
Downloads:181
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:ACTIVATION OF CLINICAL ALARMS IN THE OPERATING ROOM
Abstract:Well-implemented system of clinical alarms can save the patient's life because clinical alarms are in fact one the causes of death associated with medical technology. In the master's thesis, we described the importance of clinical alarms and how are their categorization (alarm priority). We studied the exact time of their triggering on the clinical monitor Dräger Infinity Gamma. To simulate the hemodynamic variables we used ECG simulators Simulaids and HeartSim 200. In the quantitative research, we compared the activation of the alarms in two different groups, critical alarms, and non-critical alarms. We have limited ourselves to the haemodynamic parameters measured with the Dräger Infinity Gamma Monitor. What we have found is that the alarms of critical group were activated on average in 4,37 ± 0,16 seconds, and non-critical alarms group in 8,51 ± 0,92 seconds. We have also compared the triggering of the alarms activated between fast and slow ventricular tachycardia (VT fast and slow VT). Alarm of VT fast was activated on average in 3,32 ± 0,28 seconds, what is faster than the VT slow alarm activation, which was activated on average in 5,88 ± 0,18 seconds. Simulators are able to trigger the alarms of both clinical groups and clinical monitor also recognizes and signals with the alarm.
Keywords:alarms, clinical monitor, simulations, hemodynamic monitoring


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica