Title:MERJENA ENERGETSKA IZKAZNICA
Authors:ID Sajevec, Rok (Author)
ID Praunseis, Zdravko (Mentor) More about this mentor... New window
ID Strojko, Renato (Comentor)
Files:.pdf VS_Sajevec_Rok_2015.pdf (7,69 MB)
MD5: AA7135E04C615AE8EE3AAFED80F17454
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Energy Technology
Abstract:V diplomski nalogi smo opisali merjeno energetsko izkaznico. Prikazali smo vse predhodno zbrane podatke na podlagi predhodno opravljenega vizuelnega pregleda objekta, kateri so potrebni za samo izdelavo merjene energetske izkaznice. Prikazana je izdelava merjene energetske izkaznice s pomočjo računalniškega programa KI Energija 2014. Izračunali smo vrednosti toplotnih prehodnosti s katerimi smo dokazali ustreznost oziroma neustreznost posameznih gradbenih konstrukcij objekta in te primerjali z dopustnimi vrednostmi, katere so določene v tabeli Tehnične smernice TSG-1-004-2010. Kot zadnje smo prikazali ukrepe, s katerimi bi izboljšali energetsko učinkovitost obravnavanega objekta, ter primerjavo med dejanskimi in izračunanimi vrednostmi, ter okvirni izračun vračilne dobe celotne investicije.
Keywords:merjena energetska izkaznica, Pures 2010, vizuelni pregled objekta, energetska učinkovitost, kondicionirana površina.
Place of publishing:Krško
Publisher:[R. Sajevec]
Year of publishing:2015
PID:20.500.12556/DKUM-54724 New window
UDC:536.2:721(043.2)
COBISS.SI-ID:1024219996 New window
NUK URN:URN:SI:UM:DK:AMDHLVSF
Publication date in DKUM:17.12.2015
Views:2854
Downloads:271
Metadata:XML DC-XML DC-RDF
Categories:FE
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:MEASURED ENERGY PERFORMANCE CERTIFICATE
Abstract:In this thesis, we described the Measured Energy Performance certificate. We demonstrated all of the previously collected data which were gathered on the basis of previously performed visual inspection of the object, informational data which are needed for the fabrication of the MEPC (Measured Energy Performance Certificate) itself. We demonstrated the fabrication, the process of how Measured Energy Performance certificate is produced by a computer program named “KI Energy 2014”. We calculated the values of heat transfer with whom we have proven the adequacy or inadequacy of individual building constructions of the object and compared them with the permissible values, which are set out in “Technical guidelines TSG-1-004- 2010”. At the end we have presented the important measures that could help improve the energy efficiency of the building, a comparison between the actual and calculated values as well as an indicative calculation of the return of the entire funds invested.
Keywords:measured energy performance certificate, Pures 2010, visual inspection of the building, energy efficiency, conditioned surface/area.