| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:O kontaktni leči Sensor Triggerfish : dosedanje izkušnje
Authors:ID Faschinger, Christoph (Author)
ID Faschinger, Eva (Author)
ID Krainz, Sarah (Author)
ID Mossböck, Georg (Author)
Files:URL http://www.dlib.si/details/URN:NBN:SI:doc-6XVWFWWI
 
URL https://journals.um.si/index.php/amb/article/view/1476
 
Language:English
Work type:Not categorized
Typology:1.02 - Review Article
Organization:MF - Faculty of Medicine
Abstract:Namen prispevka je prikazati novo napravo, senzorsko kontaktno lečo Triggerfish, za stalno merjenje intraokularnega pritiska, dosedanje izkušnje in oceniti možnost njene uporabe. Prikazane so do sedaj objavljene raziskave na to temo. Naprava se dobro prenaša, je varna, preiskava se lahko ponovi. Do sedaj je še premalo podatkov, da bi jo lahko uporabljali že v vsakodnevni praksi pri zdravljenju glavkoma. Potrebne bodo še dodatne raziskave.
Keywords:intraocular pressure, sensor contact lens, safety, tolerability, reproducibility, validity
Publisher:Medicinska fakulteta
Year of publishing:2012
Number of pages:str. 16-22
Numbering:Letn. 5, št. 2
PID:20.500.12556/DKUM-56821 New window
UDC:617.7
ISSN on article:1855-5640
COBISS.SI-ID:512238904 New window
NUK URN:URN:SI:UM:DK:57FONIDQ
Publication date in DKUM:30.12.2015
Views:1354
Downloads:73
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Acta medico-biotechnica : AMB
Publisher:Medicinska fakulteta, Medicinska fakulteta, Univerzitetna založba Univerze v Mariboru
ISSN:1855-5640
COBISS.SI-ID:242526720 New window

Secondary language

Language:Slovenian
Title:About the contact lens sensor Triggerfish
Abstract:The purpose is to describe the new device Triggerfish, a sensor contact lens for continuous intraocular pressure measurements, the experiences so far and to judge the possible necessity. Literature search and own publications are presented. Good tolerability and safety, good to fair reproducibility, no validity was observed. Up to now there are too less data to include this new device in every-day practice as a necessary tool for the management of glaucoma. Much more studies testing the validity are warranted.
Keywords:intraokularni pritisk, senzorska kontaktna leča, toleranca, ponovitev, ustreznost


Collection

This document is a part of these collections:
  1. Acta medico-biotechnica

Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica