Title:ANALIZA KARAKTERISTIK ENOSMERNIH IN IZMENIČNIH TALJIVIH VAROVALK
Authors:ID Praznik, Borut (Author)
ID Pihler, Jože (Mentor) More about this mentor... New window
ID Kitak, Peter (Comentor)
Files:.pdf MAG_Praznik_Borut_2016.pdf (4,18 MB)
MD5: D1572BD38EB5B96B6ECCB20D8424B558
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Magistrska naloga obravnava razliko med karakteristikami enosmernih in izmeničnih taljivih varovalk. Primerjava karakteristik je izvedena najprej kot 2D simulacija s pomočjo programa EleFAnT2D, nato pa še kot 3D simulacija s pomočjo programa EleFAnT3D. V preskusnem laboratoriju ICEM – TC so bili izvedeni preskusi na enosmernih in izmeničnih taljivih varovalkah. Nato so bili analizirani dobljeni simulacijski in merjeni rezultati.
Keywords:varovalke, nizka napetost, enosmerna napetost, izmenična napetost, kožni pojav, sosedstveni pojav
Place of publishing:[Maribor
Publisher:B. Praznik
Year of publishing:2016
PID:20.500.12556/DKUM-57538 New window
UDC:621.3.027(043.2)
COBISS.SI-ID:19465750 New window
NUK URN:URN:SI:UM:DK:WEIREDZX
Publication date in DKUM:18.03.2016
Views:2127
Downloads:227
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:AN ANALYSIS OF THE CHARACTERISTIC OF AC AND DC LOW VOLTAGE FUSES
Abstract:The master thesis discusses the difference between the characteristics of AC and DC low voltage fuses. The comparison of the characteristics is executed firstly as a 2D simulation with the help of the EleFAnT2D program and then as a 3D simulation with the help of the EleFAnT3D program. Tests on AC and DC low voltage fuses were executed in the testing laboratory ICEM – TC. The obtained simulation and measured results were later analysed.
Keywords:fuses, low voltage, direct current, alternating current, skin effect, proximity effect