| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Primerjalna analiza merjenja zunanjih premerov na 1D merilnem stroju in inkrementalnem tipalu
Authors:ID Spital, Matej (Author)
ID Ačko, Bojan (Mentor) More about this mentor... New window
Files:.pdf MAG_Spital_Matej_2016.pdf (3,99 MB)
MD5: 3CF9516B4C2DA23362D0C36420E5DC5A
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:V magistrskem delu sta predstavljeni dve različni metodi za merjenje dolžin. Osredotočili smo se na analizo točnosti meritev, izvedenih na 1D merilnem stroju ter na inkrementalnem tipalu v Laboratoriju za tehnološke meritve Fakultete za strojništvo v Mariboru. Na podlagi analize velike množice rezultatov, ki smo jih dobili pri različnih postopkih merjenja, smo ugotavljali sposobnost omenjenih merilnih sistemov. Končna analiza nam je pokazala merilno negotovost, interval zaupanja ter raztros meritev posameznega merilnega sistema. Meroslovno sposobnost merilnih sistemov smo analizirali s ponovljivostjo rezultatov meritev.
Keywords:merjenje dolžin, 1D merilni stroj, inkrementalno tipalo, merilna negotovost, sposobnost merilnega sistema
Place of publishing:Maribor
Publisher:[M. Spital]
Year of publishing:2016
PID:20.500.12556/DKUM-59122 New window
UDC:681.518.3(043.2)
COBISS.SI-ID:19745302 New window
NUK URN:URN:SI:UM:DK:PPQ3ELAV
Publication date in DKUM:03.06.2016
Views:1656
Downloads:222
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Comparative analysis of external diameter measurement on 1D measuring machine and incremental probe
Abstract:The thesis presents two different methods for measuring lengths. It is focused on the analysis of measurement accuracy, performed on the 1D measuring machine and on incremental probe in the Laboratory for ptoduction Measurement at the Faculty of Mechanical Engineering in Maribor. Based on the analysis of a large multitude of results, which were obtained by using different measurement methods, we determined the ability of both measuring systems. The final analysis demonstrates uncertainty of measurement, confidence interval and dispersion of measurement results for each measuring system. Metrology capability was determined by comparing repeatability of the measurement results.
Keywords:measuring lengths, 1D measuring machine, incremental probe, uncertainty of measurement, capability of a measuring system