Naslov:Covalent binding of heparin to functionalized PET materials for improved haemocompatibility
Avtorji:ID Kolar, Metod (Avtor)
ID Mozetič, Miran (Avtor)
ID Stana-Kleinschek, Karin (Avtor)
ID Fröhlich, Mirjam (Avtor)
ID Turk, Boris (Avtor)
ID Vesel, Alenka (Avtor)
Datoteke:.pdf Materials_2015_Kolar_et_al._Covalent_Binding_of_Heparin_to_Functionalized_PET_Materials_for_Improved_Haemocompatibility.pdf (1,70 MB)
MD5: E5BD212AD7F1702BB9D0D2977D1402D0
 
URL http://www.mdpi.com/1996-1944/8/4/1526/
 
Jezik:Angleški jezik
Vrsta gradiva:Znanstveno delo
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FS - Fakulteta za strojništvo
Opis:The hemocompatibility of vascular grafts made from poly(ethylene terephthalate) (PET) is insufficient due to the rapid adhesion and activation of blood platelets that occur upon incubation with whole blood. PET polymer was treated with NHx radicals created by passing ammonia through gaseous plasma formed by a microwave discharge, which allowed for functionalization with amino groups. X-ray photoelectron spectroscopy characterization using derivatization with 4-chlorobenzaldehyde indicated that approximately 4% of the –NH2 groups were associated with the PET surface after treatment with the gaseous radicals. The functionalized polymers were coated with an ultra-thin layer of heparin and incubated with fresh blood. The free-hemoglobin technique, which is based on the haemolysis of erythrocytes, indicated improved hemocompatibility, which was confirmed by imaging the samples using confocal optical microscopy. A significant decrease in number of adhered platelets was observed on such samples. Proliferation of both human umbilical vein endothelial cells and human microvascular endothelial cells was enhanced on treated polymers, especially after a few hours of cell seeding. Thus, the technique represents a promising substitute for wet-chemical modification of PET materials prior to coating with heparin.
Ključne besede:poly(ethylene terephthalate), vascular graft, biocompatibility, heparin, plasma, functionalization, haemolysis, platelet adhesion, endothelization
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Leto izida:2015
Št. strani:str. 1526-1544
Številčenje:Letn. 8, št. 4
PID:20.500.12556/DKUM-60193 Novo okno
ISSN:1996-1944
UDK:577
COBISS.SI-ID:28469543 Novo okno
DOI:10.3390/ma8041526 Novo okno
ISSN pri članku:1996-1944
NUK URN:URN:SI:UM:DK:VY41XAFZ
Datum objave v DKUM:21.06.2017
Število ogledov:1507
Število prenosov:388
Metapodatki:XML DC-XML DC-RDF
Področja:Ostalo
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share



Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Materials
Skrajšan naslov:Materials
Založnik:MDPI
ISSN:1996-1944
COBISS.SI-ID:33588485 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.
Začetek licenciranja:09.06.2016

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:žilni vsadki, biokompatibilnost, heparin, plazma, funkcionalizacija, hemoliza


Komentarji

Dodaj komentar

Za komentiranje se morate prijaviti.

Komentarji (0)
0 - 0 / 0
 
Ni komentarjev!

Nazaj
Logotipi partnerjev Univerza v Mariboru Univerza v Ljubljani Univerza na Primorskem Univerza v Novi Gorici