| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:SIMULACIJE SPLOŠNE ANESTEZIJE Z MINIMALNIMI PRETOKI SVEŽIH PLINOV
Authors:ID Gotovnik, Blaž (Author)
ID Križmarić, Miljenko (Mentor) More about this mentor... New window
ID Mekiš, Dušan (Comentor)
Files:.pdf MAG_Gotovnik_Blaz_2016.pdf (9,98 MB)
MD5: 86B4C5759959F8E3DC42FF266E902D3E
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Uporaba simulatorjev za izobraževanje v anesteziji ima veliko prednosti in s pomočjo le teh lahko varno raziskujemo različne situacije brez nevarnosti za bolnika. Anestezija z nizkimi pretoki ima veliko opisanih prednosti in je vse bolj pomembna tehnika v kliničnem okolju, čeprav je v povezavi z njo še vedno prisoten strah. V našem delu smo s pomočjo simulatorja METI HPS skušali ugotoviti ali obstajajo statistične razlike med spontanim in intubiranim simulatorjem, ter kaj se dogaja z simulatorjem ob različnih dostavah O2. Ugotovili smo, da med intubiranim in spontano dihajočim simulatorjem ni pomebnih statističnih razlik v vitalnih funkcijah p< 0,05. Simulator METI HPS je ustrezno simuliral premajhno dostavo O2. Ugotovili smo, da pri pretoku plinov 300 ml/min v vitalnih funkcijah v primerjavi z visokim pretokom ni razlik, povprečna vrednost SpO2 pa se celo izboljša. Ugotavljamo, da je simulator METI HPS ustreza prikazom anestezije z nizkim im metaboličnim pretokom, in je kot tak primeren za uporabo v izobraževalne namene na področju medicine in zdravstvene nege.
Keywords:Nizki pretoki anestezija, metabolični pretok, simulacije, simulator METI HPS, dostava O2.
Place of publishing:Maribor
Publisher:[B. Gotovnik]
Year of publishing:2016
PID:20.500.12556/DKUM-60725 New window
UDC:004.358:616-089.5
COBISS.SI-ID:2242468 New window
NUK URN:URN:SI:UM:DK:VTJPYUFK
Publication date in DKUM:03.10.2016
Views:1578
Downloads:219
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:SIMULATIONS OF GENERAL ANAESTHESIA WITH MINIMAL FRESH GAS FLOW
Abstract:Use of simulators for training in anesthesia has many advantages and with the help of these we can safely explore the different situations without the risk for patient. Low flow anesthesia has many advantages described, and its becoming important technique in the clinical environment, although the fear for using this technique ist stil present. In our work we use the simulator METI HPS to determine whether there are statistical differences between spontaneous breathing and intubated simulator, and what is happening with the simulator at different levels of O2 delivery. We found that betwen intubated and spontaneously breathing simulator in vital functions there is not statistical difference because the is p <0.05. HPS METI simulator properly simulate the lack of delivery of O2. We found that flow of gas 300 ml/min in the vital functions in comparison to the high flow there is no difference, and the average value of the SpO2 is even improved. We agree that the simulator METI HPS properly display low im metabolic flow in anesthesia, and as such is suitable for use in educational purposes in the field of medicine and nursing.
Keywords:Low flow anesthesia, metabolic flow, simulation, simulator METI HPS, O2 delivery


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica