Title:Zagotavljanje kakovosti elektronike vklopnega gumba kuhinjskega aparata
Authors:ID Oberč, Alenka (Author)
ID Ačko, Bojan (Mentor) More about this mentor... New window
Files:.pdf VS_Oberc_Alenka_2016.pdf (2,34 MB)
MD5: B6573C29A99A924EB55CBF3B20A79C38
 
Language:Slovenian
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:Diplomsko delo obravnava analizo merilnih sistemov za višino in vzporednost stikala glede na ravnino tiskanega vezja vklopnega gumba kuhinjskega aparata. Ti dve karakteristiki imata vpliv na varnost delovanja aparata, zato smo z namenom učinkovitega nadzora kakovosti elektronik uvedli kontrolne priprave, ki nam omogočajo tudi hitrejše in lažje izvajanje meritev, predvsem pa je izboljšana ponovljivost in obnovljivosti merilnih rezultatov. Zaradi različnih lokacij izvajanja meritev smo izvedli analizo Gage R & R z merilci na vsaki lokaciji posebej in iskali korelacijo med meritvami pri dobavitelju in meritvami v BSH.
Keywords:zagotavljanje kakovosti, analiza merilnega sistem, elektronika, kontrolna priprava
Place of publishing:Maribor
Publisher:[A. Oberč]
Year of publishing:2016
PID:20.500.12556/DKUM-61527 New window
UDC:621.3.049.77(043.2)
COBISS.SI-ID:20187670 New window
NUK URN:URN:SI:UM:DK:LICJUSI9
Publication date in DKUM:08.09.2016
Views:1668
Downloads:108
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Quality assurance of the electronics for the switch of the kitchen appliance
Abstract:This diploma thesis covers measuring systems analysis for the height and parallelism of the switch regarding the flat surface of the printed circuit board. These two characteristics have an impact on the safety operating of the appliance. With the purpose of achieving an effective quality control of electronics, we have introduced control devices which enable faster and easier performance of measurements, and in particular the repeatability and reproducibility of measurement results have been improved. Due to different locations of performing the measurements, we made a Gage R & R analysis with operators separately located on each location and searched for a correlation between the measurements performed by the supplier, and measurements performed at BSH.
Keywords:quality assurance, measuring system analysis, electronics, control device