Abstract:V diplomski nalogi smo razčlenili problematiko podjetja Forstek d.o.o., ki ima težave z dobavo komprimiranega zraka oziroma premajnim tlakom pri končnem porabniku ter previsoko temperaturo v kompresorski postaji. Preverili smo tudi, ali lahko na obstoječo tlačno posodo priključimo dodatne porabnike. Po opravljenih izračunih za padec tlaka v cevovodu, preverjanju ustreznosti tlačne posode in prezračevanja kompresorske postaje, so se v podjetju odločili za rekonstrukcijo cevovoda, zamenjavo tlačne posode in kompresorjev. Po teh ukrepih proizvodnja zopet deluje optimalno.
Keywords:komprimiran zrak, padec tlaka, dimenzioniranje cevne mreže
Place of publishing:Maribor
Publisher:[A. Poberžnik]
Year of publishing:2016
PID:20.500.12556/DKUM-61723 New window
UDC:621.51:621.643(043.2)
COBISS.SI-ID:20312854 New window
NUK URN:URN:SI:UM:DK:MCWLXI1H
Publication date in DKUM:13.09.2016
Views:1394
Downloads:253
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Reconstruction of the pipeline for the compressed air in the company Forstek d.o.o.
Abstract:In the thesis we have analysed the problem of the company Forstek d.o.o., that was having problems with the supply of compressed air, too low pressure to the final consumer and too high temperature at the compressor room. We also checked whether additional consumers could be connected to the existing air receiver. After performing the calculations for the pressure drop in the pipeline, checking the suitability of the air receiver and compressor room ventilation, the company decided to reconstruct the pipeline and change the compressor and the air receiver. After these measures have been done, the production is optimal again.
Keywords:compressed air, pressure drop, dimensioning of pipeline