Title:Možnost ponovne uporabe regeneracijske odpadne vode pri ionskem izmenjevalcu za mehčanje vode v Pivovarni Laško
Authors:ID Nemec, Nina (Author)
ID Roš, Milenko (Mentor) More about this mentor... New window
ID Hribernik, Aleš (Mentor) More about this mentor... New window
ID Škorja, Andrej (Comentor)
Files:.pdf MAG_Nemec_Nina_2016.pdf (1,85 MB)
MD5: AC1B9CA2C901B16D2E21E54C6EC0B65B
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Abstract:Pivovarska industrija je en izmed velikih porabnikov vode, ki hkrati proizvaja tudi velike količine industrijske odpadne vode, ki obremenjujejo ekosistem. Teh težav se zavedajo tudi v podjetju Pivovarna Laško, ki kot IPPC (Integrated Pollution Prevention and Control – celovito preprečevanje in nadzor onesnaževanja) zavezanec nenehno optimizira uporabo vode v proizvodnem procesu, hkrati pa skrbi za ustrezno ravnanje z odpadnimi vodami. V magistrskem delu smo raziskali možnost ponovne uporabe regeneracijske odpadne vode, ki nastaja pri mehčanju s pomočjo ionskih izmenjevalcev, v sistemu hladilnih stolpov, kar bi v prihodnosti lahko doprineslo k zmanjšanju porabe čiste vode in posledično k zmanjšanju obremenitve naravnih vodotokov. Z laboratorijskimi analizami smo določili kemijske lastnosti regeneracijske odpadne vode, kjer smo za posamezno fazo regeneracije, ki vključuje povratno pranje, kislino prenos, kislino razmestitev in izpiranje, kot tudi za skupno vzorčenje vseh faz regeneracije izmerili vrednost pH, električno prevodnost, vsebnost sulfatov, kemijsko potrebo po kisiku, motnost, m-alkaliniteto ter karbonatno in celotno trdoto. Pridobljene podatke smo nato primerjali z mejnimi vrednostmi, ki določajo kakovost vstopne vode na hladilne stolpe, ki so še dovoljene, da le-ti normalno delujejo. Ugotovili smo, da imamo opravka z zelo onesnaženimi odpadnimi vodami, kjer je za neposredno ponovno uporabo brez dodatnih metod obdelovanja primerna le prva faza regeneracije (povratno pranje), s katero bi letno pokrili le 2,6 % potreb po vodi za hladilne stolpe. Preostale faze regeneracije, kot tudi skupno zbrane faze, pa bi potrebovale dodatno čiščenje. Na voljo so številne metode čiščenja takšnih odpadnih vod, ki vključujejo nove vrste tehnologije, kemikalij, opreme in analiznih metod, poleg tega pa proizvedejo nov odpadek, ki ga je prav tako treba skrbno obdelati. Smiselno bi bilo razmisliti o načinu optimizacije celotnega procesa ionske izmenjave z uporabo dvostopenjske grobo polirne regeneracije kot tudi o ponovni uporabi regeneracijske odpadne vode v kakšne druge namene, kjer ni zahtevana visoka kakovost vstopne vode.
Keywords:Ionska izmenjava, regeneracija, regeneracijska odpadna voda, ponovna uporaba, hladilni stolpi.
Place of publishing:Maribor
Publisher:[N. Nemec]
Year of publishing:2016
PID:20.500.12556/DKUM-62708 New window
UDC:628.312.5:628.179.2(043.2)
COBISS.SI-ID:20143894 New window
NUK URN:URN:SI:UM:DK:ZWNS1CJX
Publication date in DKUM:14.10.2016
Views:2241
Downloads:305
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FS
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:The possibility of re-use of the regeneration waste water from the exchanger for water softening in the Laško brewery
Abstract:The brewing industry is one of the largest consumers of water, producing large quantities of industrial waste waters, which pollute the ecosystem. Well aware of these problems is the Laško Brewery, which, as a party liable to IPPC (Integrated Pollution Prevention and Control), constantly optimizes the use of water in the production process, while ensuring an adequate waste water treatment. In this Master thesis, we researched the potentials of reusability of regeneration waste water, a resulting product of softening by means of ion exchangers in the system of cooling towers, which would in the future contribute to the reduction of clean water consumption and consequently reduce the burden on natural watercourses. We determined the chemical properties of the regeneration waste water with laboratory analysis, where we measured the pH value, electric conductivity, the content of sulphates, chemical oxygen demand, turbidity, m-alkalinity, carbonate and total hardness of every individual stage of regeneration, which includes a backwashing, acid transfer, acid displacement and rinsing, as well as of the collective sampling of all phases of the regeneration. The data obtained were then compared with the limit values, which determine the quality of the inlet water of the cooling towers, that are still permitted in order for latter to function normally. We have established that we are dealing with highly contaminated waste waters, in which only the first stage of regeneration (backwash) would be appropriate for a direct reuse without any additional processing methods, which would annualy only cover 2,6 % of water demand for cooling towers. The remaining regeneration phases as well as the complete collective phases would require additional cleaning. There are numerous methods of cleaning such waste waters, but they − together with new types of technology, chemicals, equipment, analytical methods − produce new waste, which should also be carefully processed. It would be sensible to think about a way to optimize the entire process of ion exchange using a two-stage rough-polishing regeneration as well as the reuse of regenerative waste water for other purposes where high quality of inlet water is not required.
Keywords:Ion exchange, regeneration, regeneration waste water, reuse, cooling towers.