Abstract:V raziskavi smo merili porabo električne energije in čas molže na dveh kmetijah z različnim načinom reje in sistemom molže, ter porabo vode za pranje na obeh sistemih. Kmetija 1 ima vezan način reje z mlekovodom na štiri molzne enote, kmetija 2 pa prosto rejo z molziščem enostranski tandem (1 x 4). Povprečni čas molže posamezne krave je pri mlekovodu 7,69 minut, na molzišču pa 6,8 minut. Povprečna količina mleka na posamezno kravo je pri mlekovodu znašala 7,9 l, na molzišču pa 11,61 l. Povprečna porabljena električna energija glede količine namolzenega mleka je bila pri mlekovodu 0,29 kWh/kravo, na molzišču pa 0,25 kWh/kravo. Povprečni stroški električne energije na posamezno kravo so pri mlekovodu 0,0175 EUR, na molzišču pa 0,0151 EUR. Za eno pranje pralnega sistema se je pri mlekovodu porabilo 100 l vode, pri molzišču tandem pa 80 l vode za pranje. Do statistično značilne razlike je prišlo pri kWh na čas molže.
Keywords:mlekovod, tandem, poraba električne energije, povprečni stroški na kravo
Place of publishing:Maribor
Year of publishing:2016
PID:20.500.12556/DKUM-62916 New window
NUK URN:URN:SI:UM:DK:MKC2C499
Publication date in DKUM:09.09.2016
Views:1520
Downloads:157
Metadata:XML DC-XML DC-RDF
Categories:FKBV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:COMPARISON OF THE EFFECTIVINESS OF TANDEM MILKING AND MILK PIPELINE
Abstract:In the study, the quantity of the energy and the time used during milking were measured on two farms with different livestock housing system and different milking method and also the consuption of water for washing. The farm 1 uses the tied-stall system with milk pipelineper 4 milking units, while the farm 2 uses the free-housing system with one side tandem milking parlour (1 x 4). The average time of milking an individual cow was 7.69 minutes on the milk pipeline and 6.8 minutes on the tandem parlour. The average amount of milk per cow was 7.9 l on the milk pipeline and 11.61 l on the tandem parlour. The average electricity spent per cow regarding its quantity of milk is 0.29 kWh on the milk pipeline and 0.25 kWh on the tandem parlour. The average cost of the electricity spent per cow is 0.0175 EUR on the milk pipeline and 0,0151 EUR on the tandem parlour. For one washing of the milking system the quantity of water was 100 l on the milk pipeline and 80 l on the tandem parlour. A statistically significant difference occurred by the average amount of the electricity spent per cow regarding the time of milking.
Keywords:milkpipeline, tandem parlour, electricity consumption, average cost per cow