| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Odsesavanje anestezijskih plinov iz linearnih »mapleson« dihalnih sistemov
Authors:ID Jekl, Sebastjan (Author)
ID Križmarić, Miljenko (Mentor) More about this mentor... New window
ID Mekiš, Dušan (Comentor)
Files:.pdf MAG_Jekl_Sebastjan_2016.pdf (3,82 MB)
MD5: 1EA7BBB415F45FA4BEC02CFBBC121F95
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Teoretično izhodišče: Za zmanjševanje zdravstvenega tveganja vseh prisotnih v operacijski dvorani je potrebno odsesavanje anestezijskih plinov iz dihalnih sistemov. Osrednji namen študije je bil raziskati, kako je izvedeno odsesavanje iz linearnih dihalnih sistemov. Metodologija raziskovanja: Kvantitativno eksperimentalno študijo smo izvedli v simulacijskem okolju, kjer smo merili ustrezne tlake in pretoke znotraj sistemov odsesavanja. Uporabili smo analizator plinov Fluke VT plus HP in Dräger SAMOS basic. Eksperimente smo izvajali na anestezijski delovni postaji Dräger Primus in na Mapleson linearnih sistemih proizvajalca Intersurgical. V kliničnem okolju smo preverili, kakšno je obstoječe stanje na področju odsesavanja anestezijskih plinov. Rezultati raziskave: Ugotavljamo, da se v kliničnem okolju največkrat uporablja aktivni sistem odsesavanja. Varnostno komponento predstavlja merilec vleka v obliki plavača ter filter za prašne delce, ki ga nekatere različice imajo, druge pa ne. Pri linearnem dihalnem sistemu je novost na tržišču sistem z varnostnim ventilom, ki se priključi na sprejemni sistem in odpre pri tlaku 5 cm H2O. Vlek v sprejemni sistem se je gibal med 47 in 50 l/min. Sklep: Zaradi zamašenega filtra lahko kontaminiramo operacijsko dvorano predvsem pri uporabi funkcije visokih pretokov izpiranja (O2 FLUSH). Sklenemo lahko, da za učinkovito odsesavanje iz linearnih sistemov potrebujemo sprejemni sistem z dodatno spojko (30 mm), na katero lahko priključimo prenosni sistem, le-tega pa na APL ventil preko varnostnega ventila.
Keywords:anestezijska delovna postaja, odsesavanje anestezijskih plinov, krožni dihalni sistem, linearni dihalni sistem.
Place of publishing:Maribor
Publisher:[S. Jekl]
Year of publishing:2017
PID:20.500.12556/DKUM-64835 New window
UDC:615.4:616-089.5(043.2)
COBISS.SI-ID:2307492 New window
NUK URN:URN:SI:UM:DK:RTPSU1AX
Publication date in DKUM:01.03.2017
Views:1975
Downloads:232
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Title:Anaesthetic gas scavenging from linear »mapleson« breathing systems
Abstract:Background: efficient eliminating of waste anesthetic gases from anesthetic breathing systems is essential for reducing healthy hazards of all attendants in operating theatres. The main objective of the study was to analyze elimination of waste anesthetic gases in linear breathing systems. Materials and methods: We performed an experimental quantitative study with pressure and flow measurments in linear breathing system in the simulation laboratory. We used gas flow analyzers Fluke VT plus HF and Dräger SAMOS basic. Experiments were performed on anesthesia apparatus Dräger Primus and Mapleson linear breathing system manufactured by Intersurgical Ltd. We also revised clinical practise in our hospital for anesthesia gas scavenging. Results: In our clinical practise we mostly use an active scavenging system. The safety components in breathing systems are bowl with suction indicator (floating ball) and a dust filter, not present in all available versions. In linear breathing systems a new safety feature was recently introduced. The safety valve can be attached to the collecting system that opens at the pressure of 5 cm H2O. The flow to the collecting system was measured between 47 and 50 l/min. Conclusions: Blocked dust filter could be responsible for polluting the operating room especially when high flows are used (O2 FLUSH). We can assume that efficient and safe scavenging of waste anesthesia gases requires a collecting system with an additional conector (30 mm) for a transfer system that is attached to the APL-valve over an additional safety valve.
Keywords:Key-words: anesthesia machine, anesthesia waste gases scavenging, circle breathing system, linear breathing system.


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica