| Title: | An innovative approach to near-infrared spectroscopy using a standard mobile device and its clinical application in the real-time visualization of peripheral veins |
|---|
| Authors: | ID Jurič, Simon (Author) ID Žalik, Borut (Author) |
| Files: | BMC_Medical_Informatics_and_Decision_Making_2014_Juric,_Zalik_An_innovative_approach_to_near-infrared_spectroscopy_using_a_standard_mobi.pdf (2,32 MB) MD5: 8C566CBF87FF83F19E63C0667ADDFCCC
http://bmcmedinformdecismak.biomedcentral.com/articles/10.1186/s12911-014-0100-z
|
|---|
| Language: | English |
|---|
| Work type: | Scientific work |
|---|
| Typology: | 1.01 - Original Scientific Article |
|---|
| Organization: | FERI - Faculty of Electrical Engineering and Computer Science
|
|---|
| Abstract: | Background: Excessive venipunctures are a significant problem both in emergency rooms and during hospital stays. Near-infrared (NIR) illumination devices improve venipuncture success rate but their usage is limited by their availability and economic cost. The objectives of this study were to develop a low-cost NIR spectroscopy prototype from a standard mobile device, to evaluate its efficacy and acceptance as an educational tool, and in a clinical setting.
Methods: Through a user-centric design process a prototype device was developed. Its educational efficacy was evaluated through a non-invasive, observational study (20 student clinicians, 25 subjects) and its acceptance was assessed using quantitative and qualitative analysis. A smaller clinical trial was performed by a group of 4 medical professionals over a period of 6 weeks that involved 64 patients.
Results: The prototype enables real-time visualization of peripheral veins on a variety of Android-based devices. The prototype was 35.2% more successful in visualizing and locating veins (n = 500 attempts) than the nursing students. The acceptance assessment revealed high perception of usefulness, satisfaction, and ease of use. In the clinical trial, 1.6 (SD 1.3) additional veins per patient were identified compared with the traditional visualization methods.
Conclusions: To the best of our knowledge this is the first study that describes the design, feasibility and application of an NIR spectroscopy prototype developed on a standard mobile device. |
|---|
| Keywords: | mobile applications, spectroscopy, near-infrared, NIRS, vascular access devices, health education, feasibility |
|---|
| Publication status: | Published |
|---|
| Publication version: | Version of Record |
|---|
| Year of publishing: | 2014 |
|---|
| Number of pages: | str. 1-8 |
|---|
| Numbering: | Letn. 14 |
|---|
| PID: | 20.500.12556/DKUM-66504  |
|---|
| ISSN: | 1472-6947 |
|---|
| UDC: | 61:004.9 |
|---|
| ISSN on article: | 1472-6947 |
|---|
| COBISS.SI-ID: | 18383126  |
|---|
| DOI: | 10.1186/s12911-014-0100-z  |
|---|
| NUK URN: | URN:SI:UM:DK:UQSLHVIE |
|---|
| Publication date in DKUM: | 29.06.2017 |
|---|
| Views: | 1894 |
|---|
| Downloads: | 412 |
|---|
| Metadata: |  |
|---|
| Categories: | Misc.
|
|---|
|
:
|
Copy citation |
|---|
| | | | Average score: | (0 votes) |
|---|
| Your score: | Voting is allowed only for logged in users. |
|---|
| Share: |  |
|---|
Hover the mouse pointer over a document title to show the abstract or click
on the title to get all document metadata. |