Title:Odpornost hladilnih aparatov na motnje iz električnega omrežja
Authors:ID Jelen, Jože (Author)
ID Solar, Mitja (Mentor) More about this mentor... New window
Files:.pdf VS_Jelen_Joze_2017.pdf (2,01 MB)
MD5: FAE012227D6747025CA2CEE9A41CFD76
PID: 20.500.12556/dkum/a96547da-c647-4e15-a8f2-60c860229ed3
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V današnjem času mora vsaka elektronska naparava ustrezati standardom. Mora delovati tako, da je odporna na motnje iz omrežja in da tudi sama motenj ne pošilja v omrežje. V diplomskem delu je predstavljena primerjava odpornosti hladilnega aparata 1 in 2 z konkurenčnima hladilnima aparatoma. Predstavljeni so trije preizkusi, ki smo jih opravili po standardu in ob povečanih vrednostih (nadstandardne vrednosti). Vsi aparati ustrezajo standardom, vendar je na aparatu 1 in aparatu 2 opaženo slabše delovanje ob prisotnosti motenj. Iz meritev smo ugotovili razliko pri meritvi odpornosti na hitre prehodne pojave, kjer je osvetlitev led na aparatu 1 in 2 močno utripala in aparat je prešel v stanje, kjer kompresor ni več deloval. Rešili smo problem utripanja osvetlitve z uporabo ferita na priključnem kablu in zamenjavo triaka z zaščitnim stikalom ACS. Tako smo povečali odpornost aparata na hitre prehodne pojave in preprečili utripanje osvetlitve. S feritom smo dosegli tudi, da aparat ni več prešel v nepravilno delovanje. Rešitev se bo uporabila pri načrtovanju novih proizvodov in pri problemih na trgu oziroma pri uporabniku aparata, če bo zaznal podobne težave.
Keywords:odpornost, hladilni aparat, preizkus, motnja, standard
Place of publishing:[Maribor
Publisher:J. Jelen
Year of publishing:2017
PID:20.500.12556/DKUM-68278 New window
UDC:621.311.6:621.385(043.2)
COBISS.SI-ID:20977174 New window
NUK URN:URN:SI:UM:DK:9IVULXOI
Publication date in DKUM:23.11.2017
Views:1803
Downloads:101
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:14.09.2017

Secondary language

Language:English
Title:Immunity of refrigerating appliances to electrical network disturbances
Abstract:In this time, every electronic appliance must conform to the standards. It must operate in such a way, that it’s immune to network disturbances and does not send interference to the electrical network. The task presents a comparison of the competitive refrigerator appliances with the appliance 1 and appliance 2. Three tests were carried out according to the standards and with higher values above the standard. All appliances correspond the standards, but the appliance 1 and appliance 2 it’s less immune to disturbances. From the tests, we found the difference between appliances in the measurements of the immunity to electrical fast transient/burst, where the led lighting on appliance 1 and 2 strongly flashed and the appliance led to failure of the compressor. We solved the problem of flashing Led with ferrite on the power cable, replacing the triac with ACS protective switch. Thus, we have increased the immunity of the appliance to electrical fast transient/burst signal and prevented flashing the Led light. With ferrite, we also prevented appliance from moving into the malfunction. The solution will be used when designing new products and problems in the market and if the user of the appliance has similar problems.
Keywords:immunity, appliance, test, disturbance, standard


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica