| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Tehnologija monitoringa dinamike zeničnega refleksa s pupilometrijo
Authors:ID Trupi, Miha (Author)
ID Križmarić, Miljenko (Mentor) More about this mentor... New window
ID Strnad, Matej (Comentor)
Files:.pdf VS_Trupi_Miha_2018.pdf (1,22 MB)
MD5: 5F488F0F112F75031CA5A60B46863798
PID: 20.500.12556/dkum/70c07c00-423f-4b51-85d9-2f795da979f2
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Uvod: Zenice so del telesa katere so pomemben indikator za dokazovanje dogajanj v telesu. Prav tako je merjenje širine zenic zelo pomemben dejavnik pri diagnozi bolezni. Namen raziskave je bil analizirati spremenljivke pupilometra in v simulacijskem okolju simulirati patološki in normalni zenični refleks. Raziskovalne metode: Eksperimentalno deskriptivno študijo smo izvedli v simulacijekm okolju na simulatorju METI HPS. Za meritve zeničnega refleksa smo uporabljali pupilometer NPi-200, proizvajalca neuroptics. Normalni zenični refleks smo simulirali tako da smo na simulatorju nastavili zdravega bolnika in modelsko zasnovan odziv. Patološka scenarija sta vsebovala neodzivne zenice premera 3mm in 8 mm. Rezultati: Ugotavljamo, da je s pupilometrijo mogoče izmeriti spremenljivke kot so širina zenic, latenca širjenja oziroma oženja, zenic in poseben NPI (neurological pupil) indeks. Pri patološkem scenariju neodzivnih zenic veličine 3 mm ugotavljamo ,da aparat izmeri povprečno vrednost 3,02 ±0,09 mm. Pri neodzivnih zenicah premera 8 mm pa smo dobili povprečno vrednost 8,69 ±0,09 mm. Ostale spremenljivke pri patoloških scenarijih pričakovano niso bile prikazane. Razprava in zaključek: Ugotavljamo da je simulator ustrezno orodje za prikaz delovanja aparata kot za možnost učenja različnih scenarijev. Pri normalnih meritvah na HPS METI simulatorju, bi lahko meritve bile še bolj natančne če bi imeli zmogljivejše simulacijsko oko.
Keywords:simulacije, nevrološka stanja, HPS METI simulator, NPi-200, meritve, urgentna stanja, simulacijski center
Place of publishing:Maribor
Publisher:[M. Trupi]
Year of publishing:2018
PID:20.500.12556/DKUM-71803 New window
UDC:617:004.358(043.2)
COBISS.SI-ID:2438308 New window
NUK URN:URN:SI:UM:DK:DVDR54X0
Publication date in DKUM:05.10.2018
Views:1756
Downloads:183
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:30.08.2018

Secondary language

Language:English
Title:Technology of monitoring of the pupillary dynamic reflex with pupilometer
Abstract:Introduction: Pupils are parts of body which ones indicates, to an urgent situation in the body. Also pupils are important at diagnostic of injury. With the research we wanted to show, how to use pupilometer and what measurment are been measured at normal and patological environment. Method: We used an experimental descriptive work method. We used the device pupilometer NPi-200 from neuroptics and the simulator HPS METI. Normal pupil reflex we simulated so that we prepare the simulation doll too have the same diameter of pupils. The patological measurement where done so that we change the pupil size to 8 milimeters right pupil and 3 milimeters left one. Results: We find out that with use of pupilometer we measure wide of pupil, speed of constriction, latency and extension. This measurement are converted to NPI ( neurological pupil index). Patological measurement where measured at the wide at 3 and 8 milimeters. Average diameter of right pupil was 3,02 ±0,09 mm and average of left 8,68 ±0,09 milimeters. As expected other variables at patological measurement couldnt be done. Discussion and conclusion: At the and we came to an conclusion, that simulator can be used as an learning tool how to use products and how the product is working. At normal condition the measurement could be done more precisely if we had more efficiently simulation eye.
Keywords:simulations, neurological condition, HPS METI simulator, NPi-200, measurements, urgent situations, simulation center


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica