| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Primerjava bioprocesov s celično linijo CHO v različnih bioreaktorjih : diplomsko delo univerzitetnega študijskega programa I. stopnje
Authors:ID Košir, Matic (Author)
ID Bren, Urban (Mentor) More about this mentor... New window
ID Brinc, Matjaž (Comentor)
Files:.pdf UN_Kosir_Matic_2020.pdf (2,78 MB)
MD5: D2A03CB3A243B6509553F2B74BA6A303
PID: 20.500.12556/dkum/1df0aaa3-b1a5-4724-b72e-97e0ae83b159
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Farmacevtska industrija dandanes stremi k iskanju biološko ustreznejših rešitev in prehodu iz sintetičnih k biološkim produktom. Biofarmacevtiki predstavljajo vzpenjajoči sektor v farmacevtski industriji in so uporabni za širok spekter indikacij, vključujoč onkologijo in revmatologijo. Razvoj in optimizacija bioprocesov na laboratorijski skali je ključnega pomena za poznavanje procesa in prenos v proizvodnjo. Centralni faktor za razvoj in proizvodnjo biološkega zdravila je bioreaktor. S svojo inovativno zasnovo in visokokakovostnimi materiali mora zagotavljati optimalno in stabilno okolje za gojenje in rast celic. Zadnja leta so v porastu bioreaktorji za enkratno uporabo. Različne študije so pokazale njihove prednosti, ki so pripomogle k nadaljnjim razvojem bioloških zdravil. Tako je prišlo do razvoja nove množice bioreaktorjev, ki se razlikujejo predvsem po obliki, vnosu moči, instrumentaciji in volumnu posode za kultivacijo. Namen raziskovalnega dela je bil izvesti 14-dnevni bioproces v 4-litrskem bioreaktorskem sistemu BIOne podjetja Distek in ga primerjati z referenčnima bioprocesoma. Prvi referenčni bioproces je bil izpeljan v mikrobioreaktorskem sistemu ambr® 250, drugi pa v 1000-litrskem bioreaktorju HyClone proizvajalca Thermo Scientific. Vse bioprocese smo izvedli z istim klonom celic in pod enakimi pogoji. Bioprocesne parametre smo spremljali s pomočjo različnih sond in analitskih naprav. Pridobljene meritve smo obdelali z različnimi statističnimi metodami in jih predstavili na diagramih. Osredotočili smo se na kinetiko rasti, metabolizem in produktivnost sesalskih celic. Rezultati kažejo, da je bioreaktorski sistem pri optimalnih pogojih zagotovil uspešno izvedbo bioprocesa s sesalsko celično linijo CHO. Ugotovili smo zadovoljivo primerljivost med bioprocesi. Na podlagi preučevanih koncentracij metabolitov in substratov, osmolalnosti, kinetiko rasti in koncentracijo produkta smo zaključili, da je omenjen bioreaktorski sistem primeren za nadaljnje študije na naši laboratorijski skali. V prihodnosti nameravamo stremeti k eksperimentom z drugimi celičnimi linijami in testiranju različnih parametrov. Uspešna izvedba bi nam prinesla zaupanje v ta bioreaktorski sistem in omogočila prevzem za širšo uporabo.
Keywords:bioreaktorji za enkratno uporabo, monoklonska protitelesa, biofarmacevtika, šaržni bioproces z dohranjevanjem, kinetika in metabolizem CHO celic.
Place of publishing:Maribor
Place of performance:Maribor
Publisher:[D. Babič]
Year of publishing:2020
Number of pages:X, 39 str.
PID:20.500.12556/DKUM-76984 New window
UDC:602.4:57.086.83(043.2)
COBISS.SI-ID:33830147 New window
NUK URN:URN:SI:UM:DK:S72NJWO3
Publication date in DKUM:08.10.2020
Views:1503
Downloads:148
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC 4.0, Creative Commons Attribution-NonCommercial 4.0 International
Link:http://creativecommons.org/licenses/by-nc/4.0/
Description:A creative commons license that bans commercial use, but the users don’t have to license their derivative works on the same terms.
Licensing start date:06.08.2020

Secondary language

Language:English
Title:Comparison of bioprocesses with CHO cell line in different bioreactors
Abstract:The pharmaceutical industry nowadays is striving to find more biologically appropriate solutions and to switch from synthetic to biologic products. Biopharmaceuticals represent an emerging sector in the pharmaceutical industry and are useful for a wide range of indications, including oncology and rheumatology. The development and optimization of bioprocesses on a laboratory scale is of crucial importance to understand the process and the transfer to production. Bioreactor is the central factor for biological drug development and production. Its innovative design and high-quality materials provide an optimal and stable environment for cell growth and their cultivation. In recent years disposable bioreactors have been on the rise. Various studies have shown their benefits which have contributed to the further development of biological drugs. Thus, a new set of bioreactors has been invented which differs predominantly in shape, power input, instrumentation and in volume of the cultivation vessel. The purpose of this research was to perform a 14-day bioprocess in a 4-liter bioreactor system BIOne (Distek) and compare it with the reference bioprocesses. The first reference bioprocess was performed in a microbioreactor system ambr® 250, and the second in a 1000-liter HyClone bioreactor manufactured by Thermo Scientific. All bioprocesses were performed with the same cell clone and under the same condition. Bioprocess parameters were monitored using various probes and analytical devices. The obtained measurements were analysed with the help of various graphical methods which are further presented in diagrams. Our focus was on cell growth kinetics, metabolism, and on mammalian cell productivity. The results show that under optimal conditions the bioreactor system ensured a successful implementation of the bioprocess with the mammalian CHO cell line. We found a satisfactory comparability between the bioprocesses. It can be concluded that, based on the studied concentrations of metabolites and substrates, osmolality, growth kinetics and product concentration, the aforementioned bioreactor system is suitable for further studies on the laboratory scale. In the future, we intend to experiment with other cell lines, and to test different parameters. A successful implementation would be a guarantee of success of this bioreactor system and it would enable its acceptance for wider use.
Keywords:disposable bioreactors, monoclonal antibodies, biopharmacy, fed-batch bioprocesses, kinetics and metabolism of CHO cells.


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica