| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Analiza vplivov obratovanja statičnega sinhronskega serijskega kompenzatorja na delovanje zaščite prenosnih vodov z uporabo simulatorja v realnem času in zaprti zanki : magistrsko delo
Authors:ID Trupej, Aljaž (Author)
ID Polajžer, Boštjan (Mentor) More about this mentor... New window
ID Hrovat, Gorazd (Comentor)
Files:.pdf 2022.09.30_magistrsko_delo-Aljaz_Trupej_(2).pdf (12,08 MB)
MD5: A4D03939588C0E91C1A9DFFCA4B2156D
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:Na meddržavnem prenosnem vodu, ki povezuje razdelilni transformatorski postaji (RTP) Podlog in Obersielach, je podjetje ELES, d. o. o. (sistemski operater prenosnega omrežja) ugotovilo naraščajoči trend obremenitve. Ena izmed sodobnih rešitev je vgradnja statičnega sinhronskega serijskega kompenzatorja (SSSC – iz angl. Static Synchronous Series Compensator) v RTP Podlog, ki bi zmanjšal pretok energije na obravnavanem vodu. Naprava SSSC posredno, preko injiciranih linijskih napetosti, vpliva na reaktanco voda, kar lahko povzroči nepravilno delovanje vgrajene distančne zaščite voda. Zato smo v tej magistrski nalogi preverili vplive obratovanja naprave SSSC na delovanje distančne zaščite voda pri različnih kratkostičnih močeh bližnjega omrežja in parametrih okvare. Hkrati smo tudi preverili, kako vpliva obratovanje naprave SSSC na delovanje kombinacije distančne in diferenčne zaščite voda, ki se na meddržavnih vodih ne uporablja. Za analizo smo v zaprti zanki uporabili simulator v realnem času NovaCor, na katerega smo priključili dva komunikacijsko povezana zaščitna releja Siemens 7SD5. Rezultati so pokazali, da je naprava SSSC na delovanje distančne zaščite voda vplivala samo v 1 % izvedenih preizkusov (pri nekaterih visokoohmskih okvarah), medtem ko na delovanje diferenčne zaščite voda ni imela vpliva.
Keywords:statični sinhronski serijski kompenzator, distančna zaščita, diferenčna zaščita, digitalni simulator v realnem času, strojna oprema v zaprti zanki
Place of publishing:Maribor
Place of performance:Maribor
Publisher:[A. Trupej]
Year of publishing:2022
Number of pages:1 spletni vir (1 datoteka PDF (XX, 81 f.))
PID:20.500.12556/DKUM-83159 New window
UDC:621.316.761.2(043.2)
COBISS.SI-ID:126552579 New window
Publication date in DKUM:20.10.2022
Views:1136
Downloads:203
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:22.09.2022

Secondary language

Language:English
Title:Analysis of the Impact of a Static Synchronous Series Compensator on the Operation of Transmission Line Protection using a Hardware-In-the-Loop configuration
Abstract:On the international transmission line connecting substations Podlog and Obersielach, ELES (Slovenian transmission system operator) observed an increasing trend of overload. One of the modern solutions is an installation of a Static Synchronous Series Compensator (SSSC) in the Podlog substation, which can decrease power flow on the discussed line. SSSC indirectly, i.e. through injected line voltages, impacts the line’s reactance, and therefore it can cause incorrect operation of the implemented line distance protection relays. In the master thesis, we analyzed the impact of the SSSC on the performance of line distance protection at different short circuit capabilities of the nearby grid and fault parameters. We have also analyzed the impact of the SSSC on the performance of the combined line distance-differential protection, which is not used on international transmission lines. For the analysis, we used a Hardware-in-the-Loop configuration with the real-time digital simulator NovaCor connected with two communication-assisted protection relays Siemens 7SD5. Results show that the SSSC impacted line distance protection operation in only 1 % of cases (for some high-resistance faults), while it did not impact the operation of the line differential protection in any way.
Keywords:static synchronous series compensator, distance protection, differential protection, real-time digital simulator, Hardware-in-the-Loop