| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Obvladovanje sladkorne bolezni s sodobnimi medicinsko tehničnimi pripomočki
Authors:ID Markuš, Alen (Author)
ID Maver, Tina (Mentor) More about this mentor... New window
ID Maver, Uroš (Comentor)
ID Justinek, Damjan (Comentor)
Files:.pdf MAG_Markus_Alen_2023.pdf (2,96 MB)
MD5: 8C94D451E7BF5D3E08DEBB04E70AA9E6
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Uvod: Senzorji za merjenje glukoze v medceličnini, inzulinske črpalke s sistemom hibridne zaprte zanke in pametni inzulinski peresniki so pomemben tehnološki dosežek, ki je pripeljal do številnih koristi za bolnike, hkrati pa predstavlja nove izzive v različnih panogah, povezanih z iskanjem rešitev za boljše soočanje s sladkorno boleznijo. Senzorji omogočajo stalno spremljanje ravni glukoze v krvi, kar je izjemno pomembno za bolnike s sladkorno boleznijo, saj jim s tem omogočijo boljši nadzor in vodenje bolezni, posledično pa z dobro urejeno glikemijo živijo kakovostnejše življenje. Osredotočili smo se na stališča uporabnikove izkušnje, na drugi strani pa na pomen KMG za urejenost SB. Metode: Izvedli smo natančen pregled trga, kjer smo iskali sodobne in tehnološko napredne medicinsko-tehnične pripomočke za zdravljenje in obvladovanje sladkorne bolezni. Uporabili smo kvantitativno metodologijo raziskovanja ter validiran vprašalnik GME-Q kot orodje za oceno zadovoljstva. Rezultati: S pomočjo vprašalnika GME-Q za oceno zadovoljstva smo pridobili naslednje rezultate. Cronbachov koeficient alfa je znašal 0.919, kar odraža odlično notranjo konsistenco. Opravljena neodvisna analiza s pomočjo Cronbachovega koeficienta alfa je za vsako podlestvico znašala za učinkovitost 0.89, za priročnost 0.82 in za vsiljivost 0.757. Razprava in sklep: Rezultati naše analize kažejo, da so uporabniki zadovoljni s senzorji KMG v medceličnini. V Sloveniji je dostopnost senzorjev za KMG dobra, saj so na trgu prisotni trije proizvajalci in ima bolnik možnost izbire. Popolnoma drugačen je posnetek stanja na področju inzulinskih črpalk s sistemom hibridne zaprte zanke, saj je na trgu zgolj en proizvajalec. Pravi pametni inzulinski peresniki pa v Sloveniji sploh še niso prisotni. Tehnologija sodobnih medicinsko-tehničnih pripomočkov za zdravljenje sladkorne bolezni je pomemben tehnološki dosežek, ki se stalno nadgrajuje in izpopolnjuje, zato lahko na podlagi obstoječih raziskav trdimo, da so senzorji KMG pravi korak k izboljšanju vodenja sladkorne bolezni.
Keywords:sladkorna bolezen, management, kontinuirano merjenje glukoze, monitoring, e-zdravje, zadovoljstvo
Place of publishing:Maribor
Publisher:[A. Markuš]
Year of publishing:2023
PID:20.500.12556/DKUM-83965 New window
UDC:616.379-008.64:615.471(043.2)
COBISS.SI-ID:150429187 New window
Publication date in DKUM:18.05.2023
Views:1224
Downloads:203
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:20.03.2023

Secondary language

Language:English
Title:Diabetes management with modern medical technical devices
Abstract:Introduction: Continuous glucose monitoring sensors, insulin pumps with a hybrid closed-loop system and smart insulin pens are an important technological achievement that has opened new challenges related to diabetes management in various fields. The sensors allow continuous monitoring of blood glucose levels, which is extremely important for patients with diabetes as it allows them to better control and manage the disease and thus have a better quality of life with well-regulated blood glucose levels. We focused on the views of the user's experience and on the other hand, the importance of CGM for the regulation of SB. Methods: We conducted a systematic market search for modern and technologically advanced medical devices for the treatment and management of diabetes. We used a quantitative research methodology and a validated GME-Q questionnaire as a satisfaction assessment tool. Results: Using the GME-Q questionnaire to assess satisfaction, we obtained the following results. The Cronbach's alpha coefficient was 0.919, reflecting excellent internal consistency. Independent analysis using the Cronbach's alpha coefficient for each subscale yielded 0.89 for efficiency, 0.82 for convenience, and 0.757 for intrusiveness. Discussion and Conclusion: The results of our analysis show that users are satisfied with the CMG sensors in the intercellular space. In Slovenia, the availability of sensors for CMG sensors is good, as there are three manufacturers on the market and the patient has a choice. However, the picture is completely different for hybrid closed loop insulin pumps, as only one manufacturer is present. However, true smart insulin pens are not even present in Slovenia yet. Technology of modern medical and technical devices for the treatment of diabetes is an important technological achievement that is continuously being upgraded and improved, and based on existing research, CMG sensors are a real step towards improving diabetes management.
Keywords:diabetes, management, continuous glucose monitor, monitoring, e-health, satisfaction


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica