Title:Vpliv okolja na izmerjeno vrednost kapnometrije v predbolnišnični obravnavi
Authors:ID Globačnik, Tahi (Author)
ID Križmarić, Miljenko (Mentor) More about this mentor... New window
Files:.pdf MAG_Globacnik_Tahi_2024.pdf (1,08 MB)
MD5: 30EAFA8D3CC4891CC02915D43D82D006
 
Language:Slovenian
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FZV - Faculty of Health Sciences
Abstract:Povzetek Uvod: V predbolnišnični nujni medicinski pomoči se nemalokrat zgodi, da je potrebno bolniku nuditi dihalno podporo zaradi resnosti njegovega zdravstvenega stanja. Kapnometrija je uporabna tudi za preverjanje ustrezne namestitve sapnične cevke, oceno pljučne ventilacije, perfuzije itd. Poznamo več tehnologij merjenja delnega tlaka O2 v izdihanem zraku, vendar niso vse primerne za uporabo v predbolnišnični oskrbi bolnika. Metode: V magistrskem delu smo raziskali vpliv okolice na izmerjeno vrednost delnega tlaka ogljikovega dioksida v izdihanem zraku in opredelili njegovo uporabnost v predbolnišnični oskrbi bolnika. Z uporabo deskriptivne metode smo zbrali in analizirali podatke, s pomočjo eksplikativne metode pa iskali zveze med zanesljivostjo medicinske tehnologije in različnimi življenjskimi pogoji. Raziskavo smo opravili s prenosnim monitorjem – defibrilatorjem, ki podpira tehnologijo neposrednega vzorčenja izdihanega zraka s CO2 senzorjem. V raziskavo smo vključili podatke, ki so bili narejeni v treh prostorih z različno temperaturo in vsebnostjo vlage v zraku. Podatke smo pridobili z metodo opazovanja. Rezultati: Na podlagi raziskave, ki smo jo izvedli v treh različnih okoljih smo dokazali, da se pomembne spremembe začnejo kazati okoli pete minute raziskave in se stopnjujejo do desete minute, v okolju z visoko zračno vlažnostjo in nizko temperaturo okolja. Razprava in sklep: Zanimalo nas je, kdaj in če pride do pomembnih razlik v izmerjeni vrednosti kapnometrije, kar smo dokazali in se opredelili, da je tehnologija posrednega vzorčenja v hladnem in vlažnem okolju primernejša in zanesljivejša metoda merjenja kapnometrije. 
Keywords:neposredno vzorčenje, ogljikov dioksid, senzor, kapnografija, kapnometer
Place of publishing:Maribor
Publisher:[T. Globačnik]
Year of publishing:2024
PID:20.500.12556/DKUM-86989 New window
UDC:616.2:616-083.98(043.2)
COBISS.SI-ID:190431747 New window
Publication date in DKUM:26.03.2024
Views:445
Downloads:94
Metadata:XML DC-XML DC-RDF
Categories:FZV
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:05.02.2024

Secondary language

Language:English
Title:Environmental Impact on the Measured Value of Capnometry in Prehospital Settings
Abstract:Abstract Introduction: It often happens that a patient needs to be offered a breathing support in prehospital emergency medical care. The capnography is also useful in checking the suitability of a placement of a trachea tube, assessment of lung ventilation, perfusion, etc. Although we know various technologies of measuring the saturation of CO2 in exhaled air not all of them are suitable for prehospital medical care. In this master thesis the influence of the environment on the measurement of CO2 in exhaled air and the definition of its usability in prehospital patient care has been researched. Methods: By using the descriptive method, we have collected and analysed the data and searched for connections within reliability of medical technology and different life conditions by the explicative method. The research was done with a portable monitor – defibrillator which supports the technology of direct sampling of the exhaled air by CO2 sensor. We have included the information that was collected in three different areas with different temperature and humidity. We gathered the information by the observative method. Results: It has been proven, based on the research that has been executed in three different environments, that the significant changes start showing within the fifth minute of the research and they increase till the tenth minute in the high humidity and low temperature environment. Discussion and conclusion: We have proved that when and if it comes to important differences in measurement of value of capnography that the technology of indirect sampling in cold and humid environment is the most appropriate method of measuring capnography.
Keywords:main stream, carbon dioxide, sensor, capnograph, capnogram