Title:Izvedba rekurzivnih digitalnih sit s PLC krmilnikom : magistrsko delo
Authors:ID Dodić, Aleksandar (Author)
ID Babič, Rudolf (Mentor) More about this mentor... New window
ID Solar, Mitja (Comentor)
Files:.pdf MAG_Dodic_Aleksandar_2009_95025518.pdf (1,01 MB)
MD5: A0B79F7A3BFA2AF4F94B384E5D908B25
PID: 20.500.12556/dkum/12160f9c-a6cd-4753-9f8a-b296fa5b11f6
 
Language:Slovenian
Work type:Master's thesis
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:V nalogi je opisan postopek načrtovanja in izvedbe rekurzivnega digitalnega filtra tretje stopnje s programirnim logičnim krmilnikom. Namen filtra je izločanje neželenih signalov nizkih frekvenc pri obdelavi analognih vrednosti v sistemu industrijskega krmiljenja, ki je načrtovan s PLC krmilnikom. Pri praktični realizaciji in izračunu je uporabljen PLC krmilnik SIEMENS S7-315-DP. Kot pomoč pri vizualizaciji in analizi rezultatov je uporabljen operaterski panel S7-0P270. Za vizualizacijo smo generirali več diagramov, ki so nam pomagali pri sklepanju 0 obnašanju filtra. Ker karakteristike operaterskega panela v popolnosti ne zadoščajo zahtevam pri analizi filtra, smo bolj podrobno analizo opravili s primerjavo impulznega odziva filtra. Za praktično izvedbo smo izbrali eliptični filter, mejno frekvenco smo izbrali pri 3 Hz, frekvenca vzorčenja pa je bila 50 Hz. Primerjali smo vrednosti, katere je generiral PLC krmilnik in vrednosti, dobljene z MA TLAB-om. Pri tem smo ločeno analizirali obnašanje PLC krmilnika pri vnosu koeficientov v skrajšani obliki in ločeno za vnos v razširjeni obliki. Rezultati so prikazani za matematični model in za dejanski krmilnik. Odstopanje rezultatov za skrajšano obliko koeficientov, zaradi rekurzivnega načina obdelave, ni zanemarljivo. Digitalni filter tretje stopnje smo realizirali kot kaskadno vezavo dveh struktur prve in druge stopnje. Primerjava dejanskih vrednosti in matematične simulacije nam pokaže zelo dobro ujemanje rezultatov. Kot drugi primer uporabe digitalnega filtra smo izdelali oscilator zelo nizke frekvence. Pokazali smo, da lahko tudi za oscilator uporabimo isto digitalno strukturo implementirano v PLC krmilniku.
Keywords:digitalna obdelava signalov, digitalni filtri, rekurzivni filtri, eliptični filtri, PLC krmilniki
Place of publishing:Maribor
Publisher:A. Dodić
Year of publishing:2007
PID:20.500.12556/DKUM-9105 New window
UDC:621.391.82:621.372.54
COBISS.SI-ID:11954454 New window
NUK URN:URN:SI:UM:DK:7P0JUBTB
Publication date in DKUM:23.04.2008
Views:4375
Downloads:490
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FERI
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Secondary language

Language:English
Abstract:In master thesis is described the executing ofthird order recursive digital filter (IIR) with PLC controller. The cutoff frequency is 3 Hz and sampling frequency is 50 Hz. We made the eliptic filter. Purpose of the filter is eliminating unwanted signals at processing of analog values with PLC controller. At practic realisation and calculation there is used PLC controller Siemens S7-315-DP. As a help in visualisation in the result analysis, there is used operator panel S7-0P270. For visualisation we generated more diagrams, which had helped us at considering the behavior of the filter. Because the caracteristic of operator panel do not completely satisfing demand at the filter analysis, we made more detailed analysis with comparison of impulse response. For practical realisation, we choose elipticalfilter, cuttoff frequency was 3 Hz and sampling frequency was 50 Hz. We compared the values generated by PLC controller and values made with MATLAB. Simultaneously, we analised separately behavior of PLC controller at the input of coefficients in shortened mode and separated for input in full mode. The resu1ts are shown for mathematic model and for real controller. Alteration of the results for the shortened mode of coefficients for recursive mode of processing, is not neglible. With the same module, we realised the third order digital filter, as cascade of two second order structures. Comparision of the real values and the mathematic simulation shows very good matching between both of them. As the second example of using digital filter, we made oscilator with very low frequency. Oscilator is realised with the same circuit, but coefficients are consequently modificated, so that the circuit is out of area of stabi1ity. We shows that we can use for oscilator the same digital structure implemented in PLC controller.
Keywords:digital signal processing, digital filters, IIR filter, eliptic filter, PLC controler