Title:Optimizing carry-over in automated dissolution system dissoBOT for paracetamol and diclofenac sodium analysis
Authors:ID Majer, David (Author)
ID Šporin, Aljaž (Author)
ID Finšgar, Matjaž (Author)
Files:.pdf PIIS2472630324000529.pdf (2,77 MB)
MD5: 47A8344D5E2970ABB182291B589D5A8F
 
URL https://www.sciencedirect.com/science/article/pii/S2472630324000529?via%3Dihub
 
Language:English
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:In this work, an automated dissolution system (dissoBOT) was used for dissolution testing for the first time. Carry-over (CO) of the dissoBOT was determined for paracetamol (PA) and diclofenac sodium (DS), which are active pharmaceutical ingredients (APIs). Initially, partial method validation of the UV-VIS spectrophotometry method for PA and DS determination was performed by defining the limit of detection (LOD), the limit of quantification (LOQ), linear concentration range, accuracy, and precision. The LODs and LOQs were less than 0.01 mg/L for both APIs. The determined linear concentration ranges were from 1.00 mg/L to 30.00 mg/L for PA and from 0.50 mg/L to 3.50 mg/L for DS (the square of the correlation coefficient was greater than 0.9990, and the quality coefficient was less than 1.00 % for both APIs). The accuracy of the method was evaluated by calculating the recovery (Re) of the solutions of standards with known concentrations. The method for both APIs was deemed to be accurate (the average Re for PA and DS were 99.81 % and 101.43 %, respectively). Precision was evaluated by calculating the relative standard deviation (RSD). The method for PA and DS was deemed to be precise, as the RSD value for PA was 0.13 %, and for DS was 0.38 %. The volume (V) of the washing medium in both cleaning cycles performed by the dissoBOT system, as well as the medium dispensing V, were established, where the medium dispensing V was in accordance with the United States Pharmacopeia requirements. The CO of the dissoBOT system, using tap water as the washing medium, was determined to be less than 1.00 % for both APIs. The CO values for one cleaning cycle of the sampling station with a V of 2 mL was in the range of 1.24–1.54 %, for V of 5 mL was in the range of 0.78–0.93 %, and for V of 10 mL was in the range of 0.27–0.36 %. In addition, the CO of the dissoBOT, when employing two cleaning cycles of the sampling station (each V of 10 mL) was reduced (CO <0.20 %). Finally, the dissoBOT was successfully employed for the dissolution PA and DS tables.
Keywords:automated system, dissolution, paracetamol, diclofenac sodium, carry-over
Publication status:Published
Publication version:Version of Record
Submitted for review:04.12.2023
Article acceptance date:24.07.2024
Publication date:25.07.2024
Publisher:Elsevier Inc.
Year of publishing:2024
Number of pages:10 str.
Numbering:Vol. 29, iss. 5, [article no.] 100170
PID:20.500.12556/DKUM-91592 New window
UDC:66
ISSN on article:2472-6311
COBISS.SI-ID:203726339 New window
DOI:10.1016/j.slast.2024.100170 New window
Copyright:© 2024 The Authors
Publication date in DKUM:17.01.2025
Views:184
Downloads:14
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:SLAS technology
Shortened title:SLAS technol.
Publisher:SAGE
ISSN:2472-6311
COBISS.SI-ID:528603161 New window

Document is financed by a project

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P2-0414-2022
Name:Procesna sistemska tehnika in trajnostni razvoj

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P2-0118-2022
Name:Tekstilna kemija in napredni tekstilni materiali

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:J1-4416-2022
Name:Razvoj visokoobčutljive elektrokemijske metode na osnovi magnetnih polimernih nanokompozitov za določanje spojin antibiotikov v sledovih v okolijskih sistemih

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:J1-2470-2020
Name:Biofunkcionalizacija 3D-tiskanih kovinskih zlitin kot novo nastajajoča strategija za zmanjšanje neželenih učinkov ortopedskih vsadkov

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:avtomatski sistemi, paracetamol, natrijev diklofen


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica