| Naslov: | Multiplicative method for assessing the technical condition of switching bay devices in a substation using maintenance priorities |
|---|
| Avtorji: | ID Ribič, Janez (Avtor) ID Štumberger, Gorazd (Avtor) ID Vodenik, Marko (Avtor) ID Kerin, Uroš (Avtor) ID Bečan, Miha (Avtor) ID Šketa, Anja (Avtor) ID Bokal, Drago (Avtor) ID Kitak, Peter (Avtor) |
| Datoteke: | applsci-15-06992.pdf (1,52 MB) MD5: 151CE12520DDCCE7CB3CA0903DFD347E
https://www.mdpi.com/2076-3417/15/13/6992
|
|---|
| Jezik: | Angleški jezik |
|---|
| Vrsta gradiva: | Članek v reviji |
|---|
| Tipologija: | 1.01 - Izvirni znanstveni članek |
|---|
| Organizacija: | FERI - Fakulteta za elektrotehniko, računalništvo in informatiko
|
|---|
| Opis: | The results of the presented research are directly applicable to enhancing the maintenance strategies of transmission system operator (TSO) assets, particularly high-voltage switchyard equipment, and are extendable to other TSO systems. Furthermore, the proposed methodology lays the groundwork for the implementation of predictive maintenance. This paper introduces a novel methodology for assessing the technical condition of high-voltage switchyard devices—specifically, circuit breakers, disconnectors, and instrument transformers—within a high-voltage switching bay. The proposed model integrates multiplicative criteria, which reflect maintenance actions, and additive criteria, which capture the operational and maintenance history of individual devices. Supported by a newly developed data model, the methodology enables an automated assessment process that generates a c-curve representing the condition trajectory of each device or device type. Leveraging real-time data from the maintenance information system, this automated approach allows for the timely evaluation of a device’s technical state prior to scheduled maintenance. The resulting c-curve analysis supports strategic maintenance planning and prioritization. The proposed solutions have been implemented experimentally by TSO ELES. |
|---|
| Ključne besede: | condition-based maintenance, health index, circuit breaker, disconnector, instrument transformer, substation, failure mode analysis |
|---|
| Status publikacije: | Objavljeno |
|---|
| Verzija publikacije: | Objavljena publikacija |
|---|
| Poslano v recenzijo: | 09.05.2025 |
|---|
| Datum sprejetja članka: | 19.06.2025 |
|---|
| Datum objave: | 20.06.2025 |
|---|
| Založnik: | MDPI |
|---|
| Leto izida: | 2025 |
|---|
| Št. strani: | 31 str. |
|---|
| Številčenje: | Vol. 15, iss. 13, [article no.] 6992 |
|---|
| PID: | 20.500.12556/DKUM-93385  |
|---|
| UDK: | 621.3.077.4 |
|---|
| COBISS.SI-ID: | 240277763  |
|---|
| DOI: | 10.3390/app15136992  |
|---|
| ISSN pri članku: | 2076-3417 |
|---|
| Datum objave v DKUM: | 23.06.2025 |
|---|
| Število ogledov: | 189 |
|---|
| Število prenosov: | 24 |
|---|
| Metapodatki: |  |
|---|
| Področja: | Ostalo
|
|---|
|
:
|
Kopiraj citat |
|---|
| | | | Skupna ocena: | (0 glasov) |
|---|
| Vaša ocena: | Ocenjevanje je dovoljeno samo prijavljenim uporabnikom. |
|---|
| Objavi na: |  |
|---|
Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše
podrobnosti ali sproži prenos. |