| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Multiplicative method for assessing the technical condition of switching bay devices in a substation using maintenance priorities
Authors:ID Ribič, Janez (Author)
ID Štumberger, Gorazd (Author)
ID Vodenik, Marko (Author)
ID Kerin, Uroš (Author)
ID Bečan, Miha (Author)
ID Šketa, Anja (Author)
ID Bokal, Drago (Author)
ID Kitak, Peter (Author)
Files:.pdf applsci-15-06992.pdf (1,52 MB)
MD5: 151CE12520DDCCE7CB3CA0903DFD347E
 
URL https://www.mdpi.com/2076-3417/15/13/6992
 
Language:English
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FERI - Faculty of Electrical Engineering and Computer Science
Abstract:The results of the presented research are directly applicable to enhancing the maintenance strategies of transmission system operator (TSO) assets, particularly high-voltage switchyard equipment, and are extendable to other TSO systems. Furthermore, the proposed methodology lays the groundwork for the implementation of predictive maintenance. This paper introduces a novel methodology for assessing the technical condition of high-voltage switchyard devices—specifically, circuit breakers, disconnectors, and instrument transformers—within a high-voltage switching bay. The proposed model integrates multiplicative criteria, which reflect maintenance actions, and additive criteria, which capture the operational and maintenance history of individual devices. Supported by a newly developed data model, the methodology enables an automated assessment process that generates a c-curve representing the condition trajectory of each device or device type. Leveraging real-time data from the maintenance information system, this automated approach allows for the timely evaluation of a device’s technical state prior to scheduled maintenance. The resulting c-curve analysis supports strategic maintenance planning and prioritization. The proposed solutions have been implemented experimentally by TSO ELES.
Keywords:condition-based maintenance, health index, circuit breaker, disconnector, instrument transformer, substation, failure mode analysis
Publication status:Published
Publication version:Version of Record
Submitted for review:09.05.2025
Article acceptance date:19.06.2025
Publication date:20.06.2025
Publisher:MDPI
Year of publishing:2025
Number of pages:31 str.
Numbering:Vol. 15, iss. 13, [article no.] 6992
PID:20.500.12556/DKUM-93385 New window
UDC:621.3.077.4
ISSN on article:2076-3417
COBISS.SI-ID:240277763 New window
DOI:10.3390/app15136992 New window
Publication date in DKUM:23.06.2025
Views:192
Downloads:24
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Applied sciences
Shortened title:Appl. sci.
Publisher:MDPI
ISSN:2076-3417
COBISS.SI-ID:522979353 New window

Document is financed by a project

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P2-0115-2020
Name:Vodenje elektromehanskih sistemov

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:vzdrževanje glede na stanje, zdravstveni indeks, odklopnik, merilni transformator, podpostaja, analiza načina odpovedi


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica