| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Enhancing grid stability and low voltage ride through capability using type 2 fuzzy controlled dynamic voltage restorer
Authors:ID Sajan, Ch. (Author)
ID Satish Kumar, P. (Author)
ID Virtič, Peter (Author)
Files:.pdf Sajan_2024_Enhancing_grid_stability.pdf (1,51 MB)
MD5: B878DC7658688AC2D54D2CDB66EA0E2B
 
URL https://doi.org/10.20998/2074-272X.2024.4.04
 
Language:English
Work type:Scientific work
Typology:1.01 - Original Scientific Article
Organization:FE - Faculty of Energy Technology
Abstract:Introduction. The integration of Renewable Energy Sources (RESs), particularly Wind Energy Conversion Systems (WECS), is vital for reducing reliance on fossil fuels and addressing climate change. However, this transition poses challenges, including ensuring grid stability in the face of intermittent RESs. Compliance with grid codes is crucial, with a focus on Low Voltage Ride Through (LVRT) capability. Problem. The intermittent nature of RESs, specifically in Permanent Magnet Synchronous Generator (PMSG) based WECS, presents challenges to grid stability during voltage dips. Goal. To enhance voltage stability and LVRT capability in PMSG-based WECS by integrating a Dynamic Voltage Restorer (DVR) with an energy storage device. This involves regulating the input DC voltage to the DVR using a type 2 fuzzy controller, adapting intelligently to changing conditions. Methodology. DVR, powered by an energy storage device, is strategically integrated with WECS. A type 2 fuzzy controller regulates the DC voltage to DVR. The rectified WECS output undergoes processing through an isolated flyback converter. A 31-level Cascaded H-Bridge Multilevel Inverter (CHBMLI) with PI control ensures high-quality AC output. Results. The validation of developed system is executed using MATLAB/Simulink revealing a reduced Total Harmonic Distortion (THD) value of 1.8 %, ensuring significance in LVRT capability. Originality. The strategic integration of DVR with PMSG-based WECS, addresses the LVRT challenges. The use of type 2 fuzzy controller for intelligent voltage regulation and a sophisticated multilevel inverter contributes to the uniqueness of proposed solution. Practical value. The developed system provides benefits by ensuring reliable LVRT capability in PMSG-based WECS with reduced THD of 1.8 % indicating improved grid compatibility. References 26, tables 5, figures 20.
Keywords:permanent magnet synchronous generator, wind energy conversion systems, low voltage ride through, type 2 fuzzy controller, isolated flyback converter, 31-level cascaded H-bridge multilevel inverter, PI controller
Publication status:Published
Publication version:Version of Record
Submitted for review:07.01.2024
Article acceptance date:14.03.2024
Publication date:20.06.2024
Publisher:Elektrotehnìka ì elektromehanìka
Year of publishing:2024
Number of pages:Str. 31-41
Numbering:Št. 4
PID:20.500.12556/DKUM-93737 New window
UDC:621.3
ISSN on article:2309-3404
COBISS.SI-ID:232245251 New window
DOI:10.20998/2074-272X.2024.4.04 New window
Note:Ključne besede v slovenščini: sinhroni generator s trajnim magnetom, sistemi za pretvorbo vetrne energije, nizkonapetostni prehod, fuzzy krmilnik tipa 2, izoliran flyback pretvornik, 31-stopenjski kaskadni H-most, večstopenjski inverter, regulator PI
Publication date in DKUM:06.11.2025
Views:113
Downloads:11
Metadata:XML DC-XML DC-RDF
Categories:Misc.
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Elektrotehnìka ì elektromehanìka
Shortened title:Elektroteh. elektromeh.
Publisher:Elektrotehnìka ì elektromehanìka
ISSN:2309-3404
COBISS.SI-ID:525084441 New window

Licences

License:CC BY-NC 4.0, Creative Commons Attribution-NonCommercial 4.0 International
Link:http://creativecommons.org/licenses/by-nc/4.0/
Description:A creative commons license that bans commercial use, but the users don’t have to license their derivative works on the same terms.
Licensing start date:20.06.2024

Secondary language

Language:Ukrainian
Abstract:Вступ. Інтеграція відновлюваних джерел енергії (RESs), особливо систем перетворення енергії вітру (WECS), має життєво важливе значення для зниження залежності від викопного палива та вирішення проблеми зміни клімату. Однак цей перехід створює проблеми, у тому числі забезпечення стабільності мережі в умовах уривчастої роботи RESs. Дотримання мережевих норм має вирішальне значення, при цьому особлива увага приділяється можливості роботи при низькій напрузі (LVRT). Проблема. Уривчастий характер RESs, особливо в WECS на основі синхронного генератора з постійними магнітами (PMSG), створює проблеми для стабільності мережі під час провалів напруги. Мета. Підвищити стабільність напруги та можливості LVRT у WECS на базі PMSG за рахунок інтеграції динамічного відновника напруги (DVR) із пристроєм зберігання енергії. Це передбачає регулювання вхідної постійної напруги на DVR за допомогою нечіткого контролера типу 2, що інтелектуально адаптується до умов, що змінюються. Методологія. DVR, який працює від накопичувача енергії, стратегічно інтегрований із WECS. Нечіткий контролер типу 2 регулює напругу постійного струму, що подається на DVR. Випрямлений вихідний сигнал WECS проходить обробку через ізольований зворотноходовий перетворювач. 31-рівневий каскадний багаторівневий інвертор H-Bridge (CHBMLI) із ПІ-регулюванням забезпечує високоякісний вихід змінного струму. Результати. Валідація розробленої системи виконується з використанням MATLAB/Simulink, демонструючи зменшене значення загального гармонічного спотворення (THD) 1,8 %, що забезпечує важливість можливостей LVRT. Оригінальність. Стратегічна інтеграція DVR із WECS на базі PMSG вирішує проблеми LVRT. Використання нечіткого контролера 2-го типу для інтелектуального регулювання напруги та складного багаторівневого інвертора сприяє унікальності запропонованого рішення. Практична цінність. Розроблена система забезпечує переваги, забезпечуючи надійну роботу LVRT у WECS на базі PMSG зі зниженим THD на 1,8 %, що вказує на покращену сумісність із мережею. Бібл. 26, табл. 5, рис. 20.