| | SLO | ENG | Cookies and privacy

Bigger font | Smaller font

Show document Help

Title:Detekcija farmacevtskih učinkovin s celicami kvasovk vrste Saccharomyces cerevisiae nanešenimi na elektrokemijsko celico (biosenzor) : diplomsko delo univerzitetnega študijskega programa I. stopnje
Authors:ID Perko, Nik (Author)
ID Bren, Urban (Mentor) More about this mentor... New window
ID Štukovnik, Zala (Comentor)
Files:.pdf UN_Perko_Nik_2025.pdf (3,85 MB)
MD5: 260F4C61B1EDA12516FAD63ABD077EAE
 
Language:Slovenian
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Engineering
Abstract:Za detekcijo različnih farmacevtskih učinkovin smo uporabili impedančni biosenzor, ki je temeljil na predhodno razviti in optimizirani elektrokemijski celici z biološko komponento kvasovk vrste Saccharomyces cerevisiae. Za izdelavo elektrod smo uporabili nerjavno jeklo tipa 316, iz katerega smo sestavili trielektrodni elektrokemijski sistem v RCW side-by-side konfiguraciji. Pripravili smo različno koncentrirane raztopine acetaminofena, naproksena in izoniazida ter jih tekom meritev dodajali v zaprt elektrokemijski sistem. Stabilnost elektrokemijskega sistema smo ocenili z merjenjem potenciometrije pri odprtem tokokrogu (OCP), z elektrokemijsko impedančno spektroskopijo (EIS) pa smo spremljali odziv kvasovk vrste Saccharomyces cerevisiae na delovni elektrodi ob odsotnosti (0,9 % NaCl) in prisotnosti farmacevtskih učinkovin. Impedančni odziv sistema smo predstavili z Nyquistovimi in Bodejevimi diagrami, rezultatom pa izračunali standardni odklon, natančnost in točnost. Za vsako izmed farmacevtskih učinkovin smo oblikovali kalibracijsko krivuljo z R2 vrednostjo nad 0,95 ter izračunali mejo zaznavnosti (LOD). Za preučevanje vpliva farmacevtskih učinkovin na kvasovke vrste Saccharomyces cerevisiae smo izvedli eksperiment z rastno krivuljo, pri kateri smo spremljali spreminjanje optične gostote pri 600 nm (OD600) s časom po dodatku kontrole (0,9 % NaCl) in različno koncentriranih raztopin farmacevtskih učinkovin. Ugotovili smo, da je naš biosenzor zmožen detekcije učinka različnih koncentracij acetaminofena, naproksena in izoniazida. Dokazali smo, da z naraščanjem koncentracije naštetih farmacevtskih učinkovin pada impedanca elektrokemijskega sistema. S pripravo rastnih krivulj smo dokazali, da dodatek farmacevtskih učinkovin zavira rast celic kvasovk. Razvit biosenzor predstavlja cenovno ugodno in obetavno alternativo za hitrejšo in enostavnejšo detekcijo farmacevtskih učinkovin v vzorcih odpadne vode z uporabo živih celic kot biološke prepoznavne komponente.
Keywords:impedančni biosenzor, elektrokemijska celica, kvasovke vrste Saccharomyces cerevisiae, elektrokemijska impedančna spektroskopija (EIS), farmacevtske učinkovine
Place of publishing:Maribor
Place of performance:Maribor
Publisher:[N. Perko]
Year of publishing:2025
Number of pages:1 spletni vir (1 datoteka PDF (X, 46 str.))
PID:20.500.12556/DKUM-94240 New window
UDC:544.6:57(043.2)
COBISS.SI-ID:250648323 New window
Publication date in DKUM:15.09.2025
Views:214
Downloads:73
Metadata:XML DC-XML DC-RDF
Categories:KTFMB - FKKT
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share



Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.
Licensing start date:10.08.2025

Secondary language

Language:English
Title:Detection of pharmaceutically active compounds using yeast cells of the species Saccharomyces cerevisiae applied to an electrochemical cell (biosensor)
Abstract:A previously developed and optimised electrochemical cell was used as an impedimetric biosensor, utilizing yeast Saccharomyces cerevisiae as a biological recognition element for the detection of different pharmaceutically active compounds. Electrodes were made from type 316 stainless steel and were implemented in a three-electrode system in the RCW side-by-side configuration. Acetaminophen, naproxen, and isoniazid solutions of varying concentrations were prepared and applied to the closed electrochemical system. The stability of the electrochemical system was evaluated by measuring the open circuit potential (OCP), and electrochemical impedance spectroscopy (EIS) was employed for tracking the response of the yeast Saccharomyces cerevisiae on the working electrode in the absence (0,9% NaCl) and in the presence of pharmaceutically active compounds. The impedimetric response of the system was presented using Nyquist and Bode diagrams, and the results' standard deviation, precision, and accuracy were calculated. Moreover, we calculated the limit of detection (LOD) and devised a calibration curve for each of the studied compounds with R2 values above 0,95. To study the effect of pharmaceutically active compounds on the yeast Saccharomyces cerevisiae, an experiment using growth curves was conducted, which monitored the changes in optical density at 600 nm (OD600) over a specific time-period after the addition of the control (0,9% NaCl) and different concentrations of pharmaceutically active compounds. We found that the studied biosensor could detect different concentrations of acetaminophen, naproxen, and isoniazid, while confirming that the impedance of the electrochemical system decreases as the concentration of the compounds increases. Using growth curves, we confirmed that pharmaceutically active compounds lead to the growth inhibition of Saccharomyces cerevisiae yeast cells. The developed biosensor presents an interesting and affordable alternative for rapid and simplified detection of pharmaceutically active compounds in wastewater using living cells as the biological recognition element.
Keywords:impedimetric biosensor, electrochemical cell, yeast Saccharomyces cerevisiae, electrochemical impedance spectroscopy (EIS), pharmaceutically active compounds


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica