Naslov:Development and long–term operation of a three-dimensional displacement monitoring system for nuclear power plant piping
Avtorji:ID Lapuh, Damjan (Avtor)
ID Virtič, Peter (Avtor)
ID Štrukelj, Andrej (Avtor)
Datoteke:.pdf sensors-26-00895.pdf (11,99 MB)
MD5: CA0478A2C35758F53B43A1D00B7CCDC5
 
URL https://www.mdpi.com/1424-8220/26/3/895
 
Jezik:Angleški jezik
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FGPA - Fakulteta za gradbeništvo, prometno inženirstvo in arhitekturo
Opis:Ensuring the structural integrity of high-energy piping systems is a critical requirement for the safe operation of nuclear power plants. This paper presents the design, implementation, and three-year operational validation of a three-dimensional displacement monitoring system installed on the steam generator blowdown pipeline of the Krško Nuclear Power Plant. The system was developed to verify that the plant’s operating procedures will not induce excessive dynamic displacements during operation. The measurement system conf iguration utilizes three non-collinear inductive displacement transducers from Hottinger Baldwin Messtechnik (HBM WA/500 mm-L), mounted via miniature universal joints to a reference plate and to a defined observation point on the pipeline. This arrangement enables the real-time monitoring of X, Y, and Z displacements within a spherical measurement volume of approximately 0.5 m. Data are continuously acquired via an HBM QuantumX MX840Bamplifier and processed using CATMAN Easy-AP software through a f iber-optic communication link between the containment and control areas. The system has operated continuously for more than three years under elevated temperature and radiation conditions, confirming its reliability and robustness. The correlation of the measured displacements with process parameters such as the flow rate, pressure, and temperature provides valuable insight into transient events and contributes to predictive maintenance strategies. The presented methodology demonstrates a practical and radiation-tolerant approach for the continuous structural monitoring of nuclear plant piping systems.
Ključne besede:nuclear power plant, piping systems, displacement monitoring, inductive transducers, data acquisition, radiation environment, structural integrity, experimental diagnostics
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Poslano v recenzijo:22.11.2025
Datum sprejetja članka:20.01.2026
Datum objave:29.01.2026
Založnik:MDPI
Leto izida:2026
Št. strani:26 str.
Številčenje:Vol. 26, iss. 3, [article no.] 895
PID:20.500.12556/DKUM-97015 Novo okno
UDK:692:628.1'1
COBISS.SI-ID:267760387 Novo okno
DOI:10.3390/s26030895 Novo okno
ISSN pri članku:1424-8220
Datum objave v DKUM:11.02.2026
Število ogledov:156
Število prenosov:9
Metapodatki:XML DC-XML DC-RDF
Področja:Ostalo
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share



Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Sensors
Skrajšan naslov:Sensors
Založnik:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:jedrska elektrarna, cevovodni sistemi, spremljanje premikov, induktivni pretvorniki, pridobivanje podatkov, sevalno okolje, strukturna celovitost, eksperimentalna diagnostika


Komentarji

Dodaj komentar

Za komentiranje se morate prijaviti.

Komentarji (0)
0 - 0 / 0
 
Ni komentarjev!

Nazaj
Logotipi partnerjev Univerza v Mariboru Univerza v Ljubljani Univerza na Primorskem Univerza v Novi Gorici